Hybrid 23/25-Gauge Direct Perfluorocarbon Liquid-Silicone Oil Exchange
- PMID: 37983380
- DOI: 10.1097/IAE.0000000000003468
Hybrid 23/25-Gauge Direct Perfluorocarbon Liquid-Silicone Oil Exchange
Abstract
Purpose: To describe a novel technique for direct perfluorocarbon liquid (PFCL)-silicone oil exchange that aims to reduce the inherent risk of intraoperative intraocular pressure spike.
Methods: We use the conventional setup for passive PFCL-silicone exchange, but intentionally create a mismatch between the passive PFCL aspiration and the active silicone injection that favors the PFCL extrusion. This is achieved by converting one port to a large gauge one-23 or 20-gauge.
Results: We did not note the occurrence of high intraocular pressure spikes with this technique as noted by disk pallor or attenuated vessels.
Conclusion: A hybrid 23/25-gauge technique for direct PFCL-silicone oil exchange is safe and reduces the risk of intraoperative intraocular pressure spike.
References
-
- Petersen J. The physical and surgical aspects of silicone oil in the vitreous cavity. Graefes Arch Clin Exp Ophthalmol 1987;225:452–456.
-
- Mathis A, Pagot V, Gazagne C, Malecaze F. Giant retinal tears. Surgical techniques and results using perfluorodecalin and silicone oil tamponade. Retina 1992;12(3 Suppl):S7–S10.
-
- Wong D, Williams RL, German MJ. Exchange of perfluorodecalin for gas or oil: a model for avoiding slippage. Graefes Arch Clin Exp Ophthalmol 1998;236:234–237.
-
- Astir S, Shroff DN, Gupta C, et al. Bimanual 25-gauge chandelier technique for direct perfluorocarbon liquid-silicone oil exchange in retinal detachments associated with giant retinal tear. Indian J Ophthalmol 2018;66:1849–1851.
-
- Ahmad KT, Sallam AB, Saad AA, Ellabban AA. Fully automated direct perfluorocarbon liquid-silicone oil exchange. Clin Ophthalmol 2020;14:4355–4358.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical