Multiplexing Autoradiography
- PMID: 38006510
- DOI: 10.1007/978-1-0716-3499-8_24
Multiplexing Autoradiography
Abstract
Autoradiography, the direct imaging of radioactive distribution in tissue sections, is a powerful technique that has several key advantages for the validation of PET radiotracers. Using autoradiography, we can localize radiotracer uptake to neighbours of cells, and when multiplexed with additional radiotracers, fluorescent probes, or in situ tissue analysis, autoradiography can help to characterize the mechanism of radiotracer uptake and assess functional heterogeneity in tissue. In this chapter, the author outlines the basic ex vivo autoradiography protocol and shows how it can be multiplexed using dual radionuclides 18F and 14C. They also highlight where autoradiography can be combined with other technologies to provide synergistic information for interrogating spatial biology.
Keywords: 2-Deoxy-glucose; Autoradiography; Carbon-14; Dual radionuclides; Fluorine-18; PET; Spatial biology; Tissue sections.
© 2024. The Author(s), under exclusive license to Springer Science+Business Media, LLC, part of Springer Nature.
References
-
- Kennedy C, Des Rosiers MH, Sakurada O, Shinohara M, Reivich M, Jehle JW, Sokoloff L (1976) Metabolic mapping of the primary visual system of the monkey by means of the autoradiographic [14C]deoxyglucose technique. Proc Natl Acad Sci U S A 73(11):4230–4234. https://doi.org/10.1073/pnas.73.11.4230
-
- Serrao EM, Kettunen MI, Rodrigues TB, Dzien P, Wright AJ, Gopinathan A, Gallagher FA, Lewis DY, Frese KK, Almeida J, Howat WJ, Tuveson DA, Brindle KM (2016) MRI with hyperpolarised [1-13C]pyruvate detects advanced pancreatic preneoplasia prior to invasive disease in a mouse model. Gut 65(3):465–475. https://doi.org/10.1136/gutjnl-2015-310114
-
- Carlin S, Zhang H, Reese M, Ramos NN, Chen Q, Ricketts SA (2014) A comparison of the imaging characteristics and microregional distribution of 4 hypoxia PET tracers. J Nucl Med 55(3):515–521. https://doi.org/10.2967/jnumed.113.126615 - DOI
-
- Yamane Y, Ishide N, Kagaya Y, Takeyama D, Shiba N, Chida M, Sekiguchi Y, Nozaki T, Ido T, Shirato K (1995) Quantitative double-tracer autoradiography with tritium and carbon-14 using imaging plates: application to myocardial metabolic studies in rats. J Nucl Med 36(3):518–524
-
- Kirikae M, Diksic M, Yamamoto YL (1989) Quantitative measurements of regional glucose utilization and rate of valine incorporation into proteins by double-tracer autoradiography in the rat brain tumor model. J Cereb Blood Flow Metab 9(1):87–95. https://doi.org/10.1038/jcbfm.1989.12 - DOI
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
