. 2023 Nov 17:11:1268622.
doi: 10.3389/fped.2023.1268622. eCollection 2023.

Ultrasonographic measurements of the inferior vena cava diameter in newborns: is it a useful tool for choosing an umbilical venous catheter?

Affiliations

Ultrasonographic measurements of the inferior vena cava diameter in newborns: is it a useful tool for choosing an umbilical venous catheter?

Francesca Galdo et al. Front Pediatr. .

Abstract

Objectives: The primary outcomes of this study were to evaluate the diameters of the inferior vena cava (IVC) in a cohort of newborns and the correlation between newborn weight and IVC diameter. The secondary outcome was to evaluate the concordance between the measurements performed by the two investigators.

Methods: Two blind examiners performed an ultrasonographic (US) evaluation of the IVC diameter in neonates with a weight ranging from 2 to 4 kg. The exclusion criteria included hemodynamic instability, known vascular malformations, and major congenital malformations.

Results: A total of 143 neonates were enrolled between June 2019 and January 2021. All the US examinations were performed in the first 3 days of life. After dividing the patients into two groups according to their weight at the time of examination (2.0-2.99 kg and 3.0-4.0 kg), the median IVC diameters measured by examiner 1 were 3.1 mm (interquartile range 2.8-3.4) and 3.4 mm (interquartile range 2.9-3.8) (p = 0.003) for the two groups, respectively. The median IVC diameters measured by examiner 2 were 3.1 mm (interquartile range 2.6-3.3) and 3.3 mm (interquartile range 2.8-3.8) (p = 0.004) for the two groups, respectively. The intraclass correlation coefficient was 0.93 (95% CI: 0.90-0.95).

Conclusion: The IVC diameter values varied widely from 1.2 to 5.2 mm in newborns weighing 2-4 kg, and a low correlation between newborn weight and IVC diameter was found, so measuring IVC diameter may be a recommended step prior to inserting a umbilical venous catheter (UVC). The concordance between operators was good. We contemplated that the IVC diameter could be a potentially useful tool to identify the most appropriate UVC, thus reducing the risk of catheter-related thrombosis.

Keywords: diameter; measurements; newborn; ultrasound; umbilical catheters; vena cava.

PubMed Disclaimer

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Figures

Figure 1
Figure 1
Bland–Altman plot. LOA, 95% limit of agreement.
Figure 2
Figure 2
IVC median diameters measured by examiners 1 and 2 according to newborn weights.
Figure 3
Figure 3
Relation between newborn weight at the time of examination and IVC diameter (mean value of the two examiners).

References

    1. Young A, Harrison K, Sellwood MW. How to use… Imaging for umbilical venous catheter placement. Arch Dis Child Educ Pract Ed. (2019) 104(2):88–96. 10.1136/archdischild-2017-312662 - DOI - PubMed
    1. Rubortone SA, Costa S, Perri A, D’Andrea V, Vento G, Barone G. Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study. Ital J Pediatr. (2021) 47(1):68. 10.1186/s13052-021-01014-7 - DOI - PMC - PubMed
    1. Schlesinger AE, Braverman RM, DiPietro MA. Neonates and umbilical venous catheters: normal appearance, anomalous positions, complications, and potential aid to diagnosis. Am J Roentgenol. (2003) 180(4):1147–53. 10.2214/ajr.180.4.1801147 - DOI - PubMed
    1. Ades A, Sable C, Cummings S, Cross R, Markle B, Martin G. Echocardiographic evaluation of umbilical venous catheter placement. J Perinatol. (2003) 23(1):24–8. 10.1038/sj.jp.7210851 - DOI - PubMed
    1. Guimarães AFM, de Souza AACG, Bouzada MCF, Meira ZMA. Accuracy of chest radiography for positioning of the umbilical venous catheter. J Pediatr (Rio J). (2017) 93(2):172–8. 10.1016/j.jped.2016.05.004 - DOI - PubMed