Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 May;31(5):1898-1905.
doi: 10.1016/j.acra.2023.10.040. Epub 2023 Dec 4.

Machine Learning Methods Based on CT Features Differentiate G1/G2 From G3 Pancreatic Neuroendocrine Tumors

Affiliations

Machine Learning Methods Based on CT Features Differentiate G1/G2 From G3 Pancreatic Neuroendocrine Tumors

Hai-Yan Chen et al. Acad Radiol. 2024 May.

Abstract

Rationale and objectives: To identify CT features for distinguishing grade 1 (G1)/grade 2 (G2) from grade 3 (G3) pancreatic neuroendocrine tumors (PNETs) using different machine learning (ML) methods.

Materials and methods: A total of 147 patients with 155 lesions confirmed by pathology were retrospectively included. Clinical-demographic and radiological CT features was collected. The entire cohort was separated into training and validation groups at a 7:3 ratio. Least absolute shrinkage and selection operator (LASSO) algorithm and principal component analysis (PCA) were used to select features. Three ML methods, namely logistic regression (LR), support vector machine (SVM), and K-nearest neighbor (KNN) were used to build a differential model. Receiver operating characteristic (ROC) curves and precision-recall curves for each ML method were generated. The area under the curve (AUC), accuracy rate, sensitivity, and specificity were calculated.

Results: G3 PNETs were more likely to present with invasive behaviors and lower enhancement than G1/G2 PNETs. The LR classifier yielded the highest AUC of 0.964 (95% confidence interval [CI]: 0.930, 0.972), with 95.4% accuracy rate, 95.7% sensitivity, and 92.9% specificity, followed by SVM (AUC: 0.957) and KNN (AUC: 0.893) in the training group. In the validation group, the SVM classier reached the highest AUC of 0.952 (95% CI: 0.860, 0.981), with 91.5% accuracy rate, 97.3% sensitivity, and 70% specificity, followed by LR (AUC: 0.949) and KNN (AUC: 0.923).

Conclusions: The LR and SVM classifiers had the best performance in the training group and validation group, respectively. ML method could be helpful in differentiating between G1/G2 and G3 PNETs.

Keywords: Computed tomography; Machine learning; Neuroendocrine tumors; Pancreas.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types