Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1987 Feb;9(2):349-58.
doi: 10.1016/s0735-1097(87)80388-1.

Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy--a new method of catheter ablation

Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy--a new method of catheter ablation

S K Huang et al. J Am Coll Cardiol. 1987 Feb.

Abstract

Closed chest catheter ablation of the atrioventricular (AV) junction has been performed with direct current or laser energy. The effect of 750 kHz radiofrequency energy on ablation of the AV junction was evaluated in 13 dogs. The radiofrequency energy was generated from an electrosurgical generator in the bipolar mode. The radiofrequency output was delivered between two distal electrodes (bipolar ablation) in eight dogs, and between the distal electrode and an external patch electrode (unipolar ablation) in another five dogs at varying power (watts) but with a constant pulse duration of 10 seconds. Complete AV block was achieved in 11 dogs and second degree AV block in 2. During the 4 to 7 day follow-up period, complete AV block persisted in 9 of the 11 dogs with initial complete heart block. The other two had return of AV conduction; one had persistent 2:1 AV block and the other had persistent first degree AV block. Of the two dogs with initial second degree AV block, one developed complete AV block, the other had resumption of 1:1 AV conduction with a normal PR interval. Energy was delivered in 1 to 13 applications per dog. One hundred to 700 J per application was delivered with bipolar ablation and 10 to 100 J with unipolar ablation. There was no damage to the catheter unless the catheter was repeatedly used in excess of 1,500 J of total energy. Ventricular arrhythmias were not observed. Pathologic examination showed well delineated coagulation necrosis at the AV junction without surrounding hemorrhage or mural thrombus. Microscopic findings consisted of necrosis with cell infiltration in the periphery of necrosis. Most injuries involved the AV node, the approaches to the AV node and the penetrating bundle. In conclusion, catheter ablation of the AV junction with radiofrequency energy is safe. It can effectively induce discrete areas of necrosis and produce various degrees of AV block. In addition, ablation by radiofrequency energy has distinct advantages as compared with catheter ablation with direct current or laser energy.

PubMed Disclaimer

Publication types

LinkOut - more resources