A review of posterior chamber phakic intraocular lenses

Affiliations
Review

A review of posterior chamber phakic intraocular lenses

Dan Z Reinstein et al. Curr Opin Ophthalmol. .

Abstract

Purpose of review: Posterior chamber phakic intraocular lenses (pIOLs) are increasing in popularity as a viable alternative to laser refractive surgery. The purpose of this review is to evaluate the recent updates to pIOLs and to assess the advancements and safety of the procedure.

Recent findings: Accurate lens sizing is the key determinant to suitable vault prediction, advancements to sizing formulae including the use of very high frequency (VHF) digital ultrasound and the application of artificial intelligence and machine learning has led to improved vault prediction and safety. The introduction of the central aquaport has been shown to reduce the formation of cataract and is now adopted in most myopic pIOLs. Recently published studies have demonstrated that pIOLs have an excellent safety profile with no increased risk of retinal detachment or endothelial cell loss. Advancements have led to the introduction of extended depth of focus pIOLs for the correction of presbyopia, further research is required to evaluate the efficacy of new lens designs.

Summary: pIOL surgery is experiencing traction with improved lens design and increased lenses choices such as larger optical zone and presbyopic options. Accuracy of implantable collamer lens sizing is paramount to the safety and clinical outcomes, greater predictability is likely to encourage more posterior chamber pIOL users due to fewer sizing related complications.

PubMed Disclaimer

References

    1. Bianchi GR. Initial results from a new model of posterior chamber implantable phakic contact lens: IPCL V2.0. Med Hypothesis Discov Innov Ophthalmol 2019; 8:57–63.
    1. Jonker SMR, Berendschot T, Saelens IEY, et al. Phakic intraocular lenses: an overview. Indian J Ophthalmol 2020; 68:2779–2796.
    1. Packer M. The implantable collamer lens with a central port: review of the literature. Clin Ophthalmol 2018; 12:2427–2438.
    1. Montés-Micó R, Ruiz-Mesa R, Rodríguez-Prats JL, et al. Posterior-chamber phakic implantable collamer lenses with a central port: a review. Acta Ophthalmol 2021; 99:e288–e301.
    1. Packer M. Evaluation of the EVO/EVO+ Sphere and Toric Visian ICL: six month results from the United States Food and Drug Administration Clinical Trial. Clin Ophthalmol 2022; 16:1541–1553.