Loss of subcutaneous fat in 20 patients, both sexes, using a second-generation TECAR device of 1.240 Watts and results analyzed with magnetic resonance
- PMID: 38062900
- DOI: 10.1111/jocd.16078
Loss of subcutaneous fat in 20 patients, both sexes, using a second-generation TECAR device of 1.240 Watts and results analyzed with magnetic resonance
Abstract
Background: Body contouring and abdominal fat loss without surgery are increasingly used technique. In a study in pigs, it is noted that both capacitive and resistive radiofrequency stimulation reduced subcutaneous fat. One human study demonstrated a loss of 2.90 cm in waist diameter. Second-generation TECAR (Acronym for Transfer Electric Capacitive and Resistive) device with 4 channels, 200 cm2 work area per channel, and high power (1240 W), regulates body energy input by measuring absorption in the body and adjusting the power for 80 min at 50°C.
Aims: To evaluate the loss of subcutaneous fat, this magnitude was measured in grams and centimeters throughout the abdomen by MRI before and after each treatment.
Subject and methods: We have studied 25 patients, 13 women and 12 men with a mean age of 49 years. All patients had their waist diameter measured and an MRI performed before and after 10 continuous sessions except Saturday and Sunday, over 2 weeks. Additionally, a lipid profile was performed on the same day of the study and at the end of it. The study was approved by the Ethics Committee.
Results: Waist diameter decreased by 5.5 cm, these differences being statistically significant (p = 0.000). Subcutaneous fat measured by MRI in cm decreased by 784 cm (p = 0.000). In grams, it decreased 808.7 g (p = 0.000). In the lipid profile, all the values decreased, but they were not statistically significant.
Conclusions: The use of this second generation of TECAR equipment at 1 MHz decreases the waist diameter by more than 5 cm and leads to the loss of more than 800 grams of subcutaneous fat in 12 days. It is a method without risks or side effects, well tolerated, and an alternative for those patients who do not want to go to the operating room.
Keywords: Capenergy; MRI; high power TECAR; subcutaneous fat loss.
© 2023 The Authors. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC.
References
REFERENCES
-
- Brodie DA, Slade PD. The relationship between body-image and body-fat in adult women. Psychol Med. 1988;18(3):623-631. doi:10.1017/S0033291700008308
-
- Cash TF, Thériault J, Annis NM. Body image in an interpersonal context: adult attachment, fear of intimacy and social anxiety. J Soc Clin Psychol. 2004;23(1):89-103. doi:10.1521/jscp.23.1.89.26987
-
- Grogan S. Body image. Routledge; 2016. doi:10.4324/9781315681528
-
- Mintz LB, Kashubeck S. Body image and disordered eating among Asian American and Caucasian college students. Psychol Women Quart. 1999;23(4):781-796. doi:10.1111/j.1471-6402.1999.tb00397.x
-
- Friedmann DP. A review of the aesthetic treatment of abdominal subcutaneous adipose tissue. Dermatol Surg. 2015;41(1):18-34. doi:10.1097/DSS.0000000000000209
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical