Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 May;45(5):2165-2170.
doi: 10.1007/s10072-023-07251-4. Epub 2023 Dec 12.

The use of quantitative pupillometry in brain death determination: preliminary findings

Affiliations

The use of quantitative pupillometry in brain death determination: preliminary findings

Pavlina Lenga et al. Neurol Sci. 2024 May.

Abstract

Purpose: Quantitative pupillometry (QP) has been increasingly applied in neurocritical care as an easy-to-use and reliable technique for evaluating the pupillary light reflex (PLR). Here, we report our preliminary findings on using QP for clinical brain death (BD) determination.

Materials: This retrospective study included 17 patients ≥ 18 years (mean age, 57.3 years; standard deviation, 15.8 years) with confirmed BD, as defined by German Guidelines for the determination of BD. The PLR was tested using the NPi®-200 Pupillometer (Neuroptics, Laguna Hill, USA), a handheld infrared device automatically tracking and analyzing pupil dynamics over 3 s. In addition, pupil diameter and neurological pupil index (NPi) were also evaluated.

Results: Intracerebral bleeding, subarachnoid hemorrhage, and hypoxic encephalopathy were the most prevalent causes of BD. In all patients, the NPi was 0 for both eyes, indicating the cessation of mid-brain function. The mean diameter was 4.9 mm (± 1.3) for the right pupil and 5.2 mm (±1.2) for the left pupil.

Conclusions: QP is a valuable tool for the BD certification process to assess the loss of PLR due to the cessation of brain stem function. Furthermore, implementing QP before the withdrawal of life-sustaining therapy in brain-injured patients may reduce the rate of missed organ donation opportunities. Further studies are warranted to substantiate the feasibility and potential of this technique in treating patients and identify suitable candidates for this technique during the BD certification process.

Keywords: Brain death; Irreversibility of brain function; Organ transplantation; Pupil; Pupil diameter; Pupillary light reflex; Quantitative pupillometry.

PubMed Disclaimer

Conflict of interest statement

The authors declare no competing interests.

References

    1. A definition of irreversible coma (1968) Report of the Ad Hoc Committee of the Harvard Medical School to Examine the Definition of Brain Death. JAMA 205(6):337–340. 10.1001/jama.205.6.337 - PubMed
    1. Takeuchi K, Takeshita H, Takakura K, Shimazono Y, Handa H, Gotoh F, Manaka S, Shiogai T. Evolution of criteria for determination of brain death in Japan. Acta Neurochir. 1987;87(3–4):93–98. doi: 10.1007/BF01476058. - DOI - PubMed
    1. Sołek-Pastuszka J, Zegan-Barańska M, Biernawska J, Sawicki M, Iwańczuk W, Chełstowski K, Bohatyrewicz R, Dąbrowski W, Kojder K. Atypical pupil reactions in brain dead patients. Brain Sci. 2021;11(9):1194. doi: 10.3390/brainsci11091194. - DOI - PMC - PubMed
    1. Couret D, Boumaza D, Grisotto C, Triglia T, Pellegrini L, Ocquidant P, Bruder NJ, Velly LJ. Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study. Crit Care. 2016;20:99. doi: 10.1186/s13054-016-1239-z. - DOI - PMC - PubMed
    1. Jahns F-P, Miroz JP, Messerer M, Daniel RT, Taccone FS, Eckert P, Oddo M. Quantitative pupillometry for the monitoring of intracranial hypertension in patients with severe traumatic brain injury. Crit Care. 2019;23:155. doi: 10.1186/s13054-019-2436-3. - DOI - PMC - PubMed

LinkOut - more resources