Effect of Anterior Chamber Air on Central Corneal Thickness in Human Donor Eyes
- PMID: 38128101
- DOI: 10.1097/ICO.0000000000003457
Effect of Anterior Chamber Air on Central Corneal Thickness in Human Donor Eyes
Abstract
Purpose: The purpose of this study was to describe the effects of intracameral air on corneal edema.
Methods: A laboratory investigation was performed on human donor corneas. Baseline pachymetry measurements through anterior segment optical coherence tomography and endothelial cell density were obtained for all corneas. Each pair of corneas was separated and randomly assigned to undergo air injection or Optisol-GS into a BIONIKO artificial anterior chamber for 5 minutes at physiologic intraocular pressure confirmed by digital palpation. Photographs were obtained immediately on connection of the cornea to the artificial anterior chamber and on completion of the 5 minutes of treatment, with anterior chamber air being exchanged for Optisol-GS. Pretreatment and posttreatment photographs were obtained. Immediately after treatment, pachymetry was again obtained on all corneas. Pachymetry data underwent statistical analysis.
Results: Corneal pachymetry improved from 690.5 ± 126.6 to 576.1 ± 87.2 μm, yielding a 114.4 ± 50.4 μm improvement of pachymetry in the group with air injected into the anterior chamber. This was a significant improvement of pachymetry when compared with the group with Optisol-GS injected into the anterior chamber, which showed an improvement from 662.3 ± 126.5 to 613.5 ± 108.0 μm, yielding an improvement of 48.8 ± 34.3 μm.
Conclusions: Injection of air into the anterior chamber leads to a significant decrease in corneal pachymetry. We thereby propose that injecting air intracamerally is an effective intraoperative intervention when visualization is negatively affected by corneal edema.
Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors have no funding or conflicts of interest to disclose.
References
-
- Siddiqui A, Chamberlain WD. Descemet membrane endothelial keratoplasty in complex eyes. Curr Opin Ophthalmol. 2022;33:324–331.
-
- Venugopal A, Chandratreya MP, Ghorpade AS. A safer alternative approach to penetrating keratoplasty in opaque corneas. Indian J Ophthalmol. 2022;70:2777.
-
- Sharma N, Sahay P, Maharana PK, et al. Microscope integrated intraoperative optical coherence tomography-guided DMEK in corneas with poor visualization. Clin Ophthalmol. 2020;14:643–651.
-
- Kumar A, Yun H, Funderburgh ML, et al. Regenerative therapy for the cornea. Prog Retin Eye Res. 2022;87:101011.
-
- Doughty MJ, Jonuscheit S. Corneal structure, transparency, thickness and optical density (densitometry), especially as relevant to contact lens wear-a review. Cont Lens Anterior Eye. 2019;42:238–245.