Observational Study
. 2024 May:62:40-47.
doi: 10.1016/j.carrev.2023.12.007. Epub 2023 Dec 16.

Comparison of ultrasound- versus fluoroscopy-guidEd femorAl access In tranS-catheter aortic valve replacement In the Era of contempoRary devices: The EASIER registry

Affiliations
Observational Study

Comparison of ultrasound- versus fluoroscopy-guidEd femorAl access In tranS-catheter aortic valve replacement In the Era of contempoRary devices: The EASIER registry

Emiliano Bianchini et al. Cardiovasc Revasc Med. 2024 May.

Abstract

Background: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention.

Methods: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest.

Results: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4).

Conclusions: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.

Keywords: Femoral access management; Fluoroscopy; Puncture guidance; TAVR; Ultrasound; Vascular complication.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest Giuseppe Biondi-Zoccai has consulted for Amarin, Balmed, Cardionovum, Crannmedical, Endocore Lab, Eukon, Guidotti, Innovheart, Meditrial, Microport, Opsens Medical, Terumo, and Translumina, outside the present work. All other authors report no conflict of interest. Cristina Aurigemma has been involved in advisory board activities by Abbott, Abiomed, Medtronic, and Biotronic. Enrico Romagnoli received speaker fees from St. Jude. Carlo Trani and Francesco Burzotta received speakers' fees from Abbott Vascular, Abiomed, Medtronic and Terumo. The other authors have no conflicts of interest to declare.

MeSH terms