Ultrasound-based Accuro system versus traditional palpation technique for neuraxial anaesthesia: A systematic review and meta-analysis of randomised controlled trials
- PMID: 38149589
- DOI: 10.1177/17504589231215927
Ultrasound-based Accuro system versus traditional palpation technique for neuraxial anaesthesia: A systematic review and meta-analysis of randomised controlled trials
Abstract
Introduction: This review evaluates the efficacy and safety of Accuro, a handheld ultrasound device, compared to the palpation technique for neuraxial anaesthesia. Accuro provides real-time imaging guidance, potentially improving accuracy and efficiency.
Methods: A comprehensive search across six electronic databases identified randomised clinical trials comparing Accuro with palpation for neuraxial anaesthesia. Risk ratios or mean differences with 95% confidence intervals (CIs) were calculated using a random-effects model. Bias risk was evaluated using the Cochrane Risk of Bias tool.
Results: Five studies (n=369) met the inclusion criteria. Accuro showed a favourable risk ratio for first insertion success (1.44 [95% CI [1.01, 2.05], p=0.05]). It significantly reduced needle skin passes (MD -0.63; 95% CI [-1.05, -0.21]; p<0.01), but not needle redirection (MD -1.31; 95% CI [-2.71, 0.11]; p=0.07). Procedure time was shorter in palpation (MD 127.82; 95% CI [8.68, -246.97]; p=0.04). Four studies had a low risk of bias; one had some concerns.
Conclusion: Accuro can potentially improve success rates and reduce skin passes in neuraxial anaesthesia. Further trials with larger samples are needed, especially in patients with anticipated difficulties.
Keywords: Accuro; First pass success rate; Handheld ultrasound; Landmark-based neuraxial technique; Number of needle redirections; Number of skin attempts; Preprocedural ultrasound; SpineNav3DTM.
Conflict of interest statement
Declaration of conflicting interestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship and/or publication of this article.
Similar articles
-
The use of ultrasound guidance for perioperative neuraxial and peripheral nerve blocks in children.Cochrane Database Syst Rev. 2016 Feb 19;2(2):CD011436. doi: 10.1002/14651858.CD011436.pub2. Cochrane Database Syst Rev. 2016. Update in: Cochrane Database Syst Rev. 2019 Feb 27;2:CD011436. doi: 10.1002/14651858.CD011436.pub3. PMID: 26895372 Free PMC article. Updated.
-
Interventions for the treatment of brain radionecrosis after radiotherapy or radiosurgery.Cochrane Database Syst Rev. 2018 Jul 9;7(7):CD011492. doi: 10.1002/14651858.CD011492.pub2. Cochrane Database Syst Rev. 2018. PMID: 29987845 Free PMC article.
-
Comparison of ultrasound-guided and traditional localisation in intraspinal anesthesia: a systematic review and network meta-analysis.BMJ Open. 2023 Nov 2;13(11):e071253. doi: 10.1136/bmjopen-2022-071253. BMJ Open. 2023. PMID: 37918920 Free PMC article.
-
Systemic pharmacological treatments for chronic plaque psoriasis: a network meta-analysis.Cochrane Database Syst Rev. 2021 Apr 19;4(4):CD011535. doi: 10.1002/14651858.CD011535.pub4. Cochrane Database Syst Rev. 2021. Update in: Cochrane Database Syst Rev. 2022 May 23;5:CD011535. doi: 10.1002/14651858.CD011535.pub5. PMID: 33871055 Free PMC article. Updated.
-
Ultrasound guidance for arterial (other than femoral) catheterisation in adults.Cochrane Database Syst Rev. 2021 Oct 12;10(10):CD013585. doi: 10.1002/14651858.CD013585.pub2. Cochrane Database Syst Rev. 2021. PMID: 34637140 Free PMC article.
Cited by
-
uSINE-PAMS Artificial Intelligence-Driven, Ultrasound-Guided Lumbar Puncture to Improve Procedural Accuracy: A Pilot Study Report.Neurol Clin Pract. 2025 Apr;15(2):e200447. doi: 10.1212/CPJ.0000000000200447. Epub 2025 Feb 25. Neurol Clin Pract. 2025. PMID: 40201070
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous