Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic Control
- PMID: 38156962
- DOI: 10.1089/dia.2023.0460
Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic Control
Abstract
Background: Few studies have evaluated the implications of the alarm thresholds of continuous glucose monitoring (CGM) systems for individuals with diabetes. The present study aimed to investigate the influence of hypoglycemia and hyperglycemia alarm thresholds on glycemic control in adults with type 1 diabetes (T1DM) and the characteristics of patients who use these alarms more frequently. Methods: This observational cross-sectional study included 873 users of the FreeStyle Libre 2 system (501 men, median age 48 years, range 18-90 years) with T1DM from a single center. We investigated the role of demographic and metabolic factors on the use of alarms and the impact of hypoglycemia and hyperglycemia alarms and their thresholds on glycemic control. Results: Alarm users were older than nonusers (median age 49 vs. 43 years, respectively; P < 0.001). The hypoglycemia alarms were set by 76.1% of women and by 69.1% of men (P = 0.022). The hypoglycemia alarms reduced hypoglycemia features and glucose variability, although at the expense of shorter time in range. The higher the hypoglycemia alarm threshold, the greater these effects. The hyperglycemia alarms were effective in reducing hyperglycemia and lowering the glucose management indicator, although at the expense of a greater tendency to hypoglycemia. The lower the hyperglycemia alarm threshold, the greater these effects. Conclusions: CGM alarms contribute to better glycemic control. However, hypoglycemia and hyperglycemia alarms have advantages and disadvantages. Adults with T1DM should explore, under medical supervision, which alarm thresholds will best help them achieve their individual glycemic goals.
Keywords: Alarm; Continuous glucose monitoring; Glucose variability; Hypoglycemia; Type 1 diabetes.
Similar articles
-
Intermittent-scanned continuous glucose monitoring with low glucose alarms decreases hypoglycemia incidence in middle-aged adults with type 1 diabetes in real-life setting.J Diabetes Complications. 2023 Feb;37(2):108385. doi: 10.1016/j.jdiacomp.2022.108385. Epub 2022 Dec 26. J Diabetes Complications. 2023. PMID: 36603333
-
[High-rank technology in the medicine - the impact of continuous glucose monitoring system alarm settings values on glycemic control in type 1 diabetes patients: a systematic review].Vnitr Lek. 2021 Winter;67(6):346-350. Vnitr Lek. 2021. PMID: 35459377 Czech.
-
Hypoglycemia detection in critical care using continuous glucose monitors: an in silico proof of concept analysis.J Diabetes Sci Technol. 2010 Jan 1;4(1):15-24. doi: 10.1177/193229681000400103. J Diabetes Sci Technol. 2010. PMID: 20167163 Free PMC article.
-
Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.J Diabetes Sci Technol. 2010 Nov 1;4(6):1457-64. doi: 10.1177/193229681000400620. J Diabetes Sci Technol. 2010. PMID: 21129341 Free PMC article. Clinical Trial.
-
Limitations of 14-Day Continuous Glucose Monitoring Sampling for Assessment of Hypoglycemia and Glycemic Variability in Type 1 Diabetes.Diabetes Technol Ther. 2024 Jul;26(7):503-508. doi: 10.1089/dia.2023.0476. Epub 2024 Feb 16. Diabetes Technol Ther. 2024. PMID: 38300516 Review.
Cited by
-
Glucose metrics and device satisfaction in adults with type 1 diabetes using different treatment modalities: a multicenter, real-world observational study.Acta Diabetol. 2025 Apr;62(4):563-573. doi: 10.1007/s00592-024-02381-3. Epub 2024 Oct 10. Acta Diabetol. 2025. PMID: 39387915 Free PMC article.
-
Duration of type 1 diabetes and glycaemic control in adults: A nonlinear relationship.Diabetes Obes Metab. 2025 Jul;27(7):4001-4006. doi: 10.1111/dom.16392. Epub 2025 Apr 14. Diabetes Obes Metab. 2025. PMID: 40223475 Free PMC article. No abstract available.
-
Glucose alarms approach with flash glucose monitoring system: a narrative review of clinical benefits.Diabetol Metab Syndr. 2025 Jul 16;17(1):276. doi: 10.1186/s13098-025-01797-3. Diabetol Metab Syndr. 2025. PMID: 40671052 Free PMC article. Review.
-
Post-hypoglycemic nocturnal hyperglycemia in type 1 diabetes: the Somogyi hypothesis revisited.Hormones (Athens). 2025 Jun 4. doi: 10.1007/s42000-025-00680-0. Online ahead of print. Hormones (Athens). 2025. PMID: 40465171
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical