Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024:2742:69-76.
doi: 10.1007/978-1-0716-3561-2_5.

A Step-by-Step Guide to Selecting an Optimal Cut-Off Value Based on the Receiver Operating Characteristic and Youden Index in Methods Designed to Diagnose Lyme Disease

Affiliations

A Step-by-Step Guide to Selecting an Optimal Cut-Off Value Based on the Receiver Operating Characteristic and Youden Index in Methods Designed to Diagnose Lyme Disease

Kunal Garg et al. Methods Mol Biol. 2024.

Abstract

Detection tools designed to diagnose complex diseases such as Lyme Borreliosis require an optimal cutoff point to distinguish the healthy from the diseased. The chapter will provide a practical guide to selecting an optimal cutoff mark by creating the receiver operating characteristic (ROC) in Microsoft Excel. To guide the creation of a ROC graphical plot, we will use example data from an enzyme-linked immunosorbent assay (ELISA) measuring anti-human immunoglobulin G (IgG) against whole-cell Borrelia lysates. Herein, the ROC method will demonstrate that an optical density (OD) value from ELISA with the highest Youden Index (J) is an optimal cutoff value to differentiate positive and negative IgG immune responses in human serum samples.

Keywords: Microsoft Excel ROC; Optimal cutoff; Receiver Operating Characteristic; Sensitivity; Specificity; Youden Index.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Lardeux F, Torrico G, Aliaga C (2016) Calculation of the ELISA’s cut-off based on the change-point analysis method for detection of Trypanosoma cruzi infection in Bolivian dogs in the absence of controls. Mem Inst Oswaldo Cruz 111(8):501–504. https://doi.org/10.1590/0074-02760160119 - DOI - PubMed - PMC
    1. Greiner M, Sohr D, Göbel P (1995) A modified ROC analysis for the selection of cut-off values and the definition of intermediate results of serodiagnostic tests. J Immunol MetH 185(1):123–132. https://doi.org/10.1016/0022-1759(95)00121-p - DOI
    1. Richardson MD, Turner A, Warnock DW et al (1983) Computer-assisted rapid enzyme-linked immunosorbent assay (ELISA) in the serological diagnosis of aspergillosis. J Immunol Meth 56:201–207. https://doi.org/10.1016/0022-1759(83)90412-X - DOI
    1. Gupta N, Chaudhry R, Thakur CK (2016) Determination of cutoff of ELISA and immunofluorescence assay for scrub typhus. J Glob Infect Dis 8(3):97–99. https://doi.org/10.4103/0974-777X.188584 - DOI - PubMed - PMC
    1. Zweig MH, Campbell G (1993) Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem 39(4):561–577. https://doi.org/10.1093/clinchem/39.4.561 - DOI - PubMed

Substances

LinkOut - more resources