. 2024 Mar;36(3):520-526.
doi: 10.1111/jerd.13182. Epub 2024 Jan 3.

In-vivo repeatability of three intra-oral spectrophotometers

Affiliations

In-vivo repeatability of three intra-oral spectrophotometers

Vincent Hampé-Kautz et al. J Esthet Restor Dent. 2024 Mar.

Abstract

Objective: The objective was to assess the repeatability of three spectrophotometers, based on the CIELCh factors and shadeguide reference measurements.

Materials and methods: Color analysis was performed using three devices: Rayplicker, Easyshade 4, and Easyshade V. Five repeated measures were performed by the same operator, on the right central maxillary incisor of 30 patients. The CIELCh factors were retrieved and the intra-class correlation was calculated. The Vita Classical and Vita 3D Master shadeguides were used to evaluate the respective Fleiss' Kappa factors.

Results: Rayplicker and Easyshade V demonstrated strong intra-class correlation based on the CIELCh factors: 0.98, 0.99, and 0.91 for Rayplicker, and 0.95, 0.99, and 0.93 for Easyshade V, for the L*, C*, and h* parameters, respectively. Regarding the repeatability of the shadeguide data, while Easyshade 4 had the best repeatability when using the Vita Classical as a reference, Rayplicker and Easyshade V showed better repeatability when using the Vita 3D Master.

Conclusion: These findings suggest that both Rayplicker and Easyshade V are reliable devices for measuring CIELCh parameters. In terms of shadeguide references, the reliability of spectrophotometers is generally lower compared to the CIELCh measurements.

Clinical significance: Given their good repeatability, both the Rayplicker and the Easyshade V spectrophotometers are reliable tools for prosthetic dental practices.

Keywords: L* C* h*; Rayplicker; repeatability; shade analysis; spectrophotometer.

PubMed Disclaimer

References

REFERENCES

    1. Carek A, Brkić B, Cigić M, Jelavić I, Kurilić A. Fixed prosthodontic patient satisfaction survey. Psychiatr Danub. 2021;33(Suppl 4):1320-1326.
    1. Paravina R, Powers JM. Esthetic Color Training in Dentistry. Mosby; 2004:272.
    1. Chen H, Huang J, Dong X, et al. A systematic review of visual and instrumental measurements for tooth shade matching. Quintessence Int Berl Ger 1985. 2012;43(8):649-659.
    1. Clary JA, Ontiveros JC, Cron SG, Paravina RD. Influence of light source, polarization, education, and training on shade matching quality. J Prosthet Dent. 2016;116(1):91-97.
    1. Paravina RD, Powers JM, Fay RM. Dental color standards: shade tab arrangement. J Esthet Restor Dent. 2001;13(4):254-263.