Assessment of the feasibility of 1-min sit-to-stand test in evaluating functional exercise capacity in interstitial lung disease patients
- PMID: 38188134
- PMCID: PMC10766448
- DOI: 10.12965/jer.2346418.209
Assessment of the feasibility of 1-min sit-to-stand test in evaluating functional exercise capacity in interstitial lung disease patients
Abstract
Six-min walk test (6MWT) is widely used exercise test for the evaluation of interstitial lung disease (ILD). However, the long test duration and need for long and flat surface hinder its routine use. One-min sit-to-stand test (1-STST) is devoid of such limitations, but has been scarcely evaluated. The study was conducted to evaluate the performance of 1-STST by correlating it with 6MWT in ILD patients. Stable ILD patients were prospectively enrolled. After initial spirometry, all patients performed 6MWT and 1-STST following the standard recommendations. Exercise capacity and physiological parameters (heart rate, pulse oxygen saturation, blood pressure and dyspnea [modified Borg scale]) including peripheral oxygen saturation (SpO2) were correlated after the tests using Pearson correlation, Intraclass correlation coefficient (ICC) and kappa (κ) coefficient. The results showed that the mean age of the patients (n=60) was 58.8±11.5 years (male:female=1:1). Repetitions after 1-STST showed significant correlation with 6MWT (r=0.48; P<0.001). Changes in the physiological variables were similar (P>0.05) with good consistency (ICC=0.68-0.95) between 6MWT and 1-STST. Both lowest SpO2 and difference in SpO2 also showed good agreement (ICC=0.86; 95% confidence interval [CI], 0.77-0.92 and ICC=0.68; 95% CI, 0.47-0.81 respectively) and significant correlation (r=0.76 and r=0.52, respectively). 1-STST and 6MWT were consistent in identifying patients having oxygen desaturation ≥4% (κ=0.56; 96% CI, 0.30-0.82). The results demonstrated that the performance of 1-STST was consistent with 6MWT in terms of exercise capacity and change in physiological parameters. 1-STST can be a valid alternative to 6MWT in the assessment of ILD patients, especially in peripheral health centers.
Keywords: Exercise capacity; Interstitial lung disease; One-minute sit-to-stand test; Six-minute walk test.
Copyright © 2023 Korean Society of Exercise Rehabilitation.
Conflict of interest statement
CONFLICT OF INTEREST No potential conflict of interest relevant to this article was reported.
Figures
References
-
- ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002;166:111–117. - PubMed
-
- Bennett D, Fossi A, Bargagli E, Refini RM, Pieroni M, Luzzi L, Ghiribelli C, Paladini P, Voltolini L, Rottoli P. Mortality on the waiting list for lung transplantation in patients with idiopathic pulmonary fibrosis: a single-centre experience. Lung. 2015;193:677–681. - PubMed
-
- Bohannon RW, Crouch R. 1-minute sit-to-stand Test: systematic review of procedures, performance, and clinimetric properties. J Cardiopulm Rehabil Prev. 2019;39:2–8. - PubMed
-
- Bui KL, Nyberg A, Maltais F, Saey D. Functional tests in chronic obstructive pulmonary disease, part 1: clinical relevance and links to the international classification of functioning, disability, and health. Ann Am Thorac Soc. 2017;14:778–784. - PubMed
LinkOut - more resources
Full Text Sources
