Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor
- PMID: 38196822
- PMCID: PMC10776092
- DOI: 10.1109/JTEHM.2023.3329344
Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor
Abstract
Background: Several validated clinical scales measure the severity of essential tremor (ET). Their assessments are subjective and can depend on familiarity and training with scoring systems.
Method: We propose a multi-modal sensing using a wearable inertial measurement unit for estimating scores on the Fahn-Tolosa-Marin tremor rating scale (FTM) and determine the classification accuracy within the tremor type. 17 ET participants and 18 healthy controls were recruited for the study. Two movement disorder neurologists who were blinded to prior clinical information viewed video recordings and scored the FTM. Participants drew a guided Archimedes spiral while wearing an inertial measurement unit placed at the mid-point between the lateral epicondyle of the humerus and the anatomical snuff box. Acceleration and gyroscope recordings were analyzed. The ratio of the power spectral density between frequency bands 0.5-4 Hz and 4-12 Hz, and the sum of power spectrum density over the entire spectrum of 2-74 Hz, for both accelerometer and gyroscope data, were computed. FTM was estimated using regression model and classification using SVM was validated using the leave-one-out method.
Results: Regression analysis showed a moderate to good correlation when individual features were used, while correlation was high ([Formula: see text] = 0.818) when suitable features of the gyro and accelerometer were combined. The accuracy for two-class classification of the combined features using SVM was 91.42% while for four-class it was 68.57%.
Conclusion: Potential applications of this novel wearable sensing method using a wearable Inertial Measurement Unit (IMU) include monitoring of ET and clinical trials of new treatments for the disorder.
Keywords: Essential tremor; Fahn-Tolosa-Marin tremor rating scale; inertial measurement unit; wearables.
© 2023 The Authors.
Figures



Similar articles
-
Assessing Parkinson's Rest Tremor from the Wrist with Accelerometry and Gyroscope Signals in Patients with Deep Brain Stimulation: An Observational Study.J Clin Med. 2025 Mar 18;14(6):2073. doi: 10.3390/jcm14062073. J Clin Med. 2025. PMID: 40142880 Free PMC article.
-
Wearable sensors during drawing tasks to measure the severity of essential tremor.Sci Rep. 2022 Mar 28;12(1):5242. doi: 10.1038/s41598-022-08922-6. Sci Rep. 2022. PMID: 35347169 Free PMC article.
-
A Novel Accelerometry Method to Perioperatively Quantify Essential Tremor Based on Fahn-Tolosa-Marin Criteria.J Clin Med. 2023 Jun 23;12(13):4235. doi: 10.3390/jcm12134235. J Clin Med. 2023. PMID: 37445270 Free PMC article.
-
Intelligent devices for assessing essential tremor: a comprehensive review.J Neurol. 2024 Aug;271(8):4733-4750. doi: 10.1007/s00415-024-12354-9. Epub 2024 May 31. J Neurol. 2024. PMID: 38816480 Review.
-
Quantification of the validity and reliability of sprint performance metrics computed using inertial sensors: A systematic review.Gait Posture. 2019 Sep;73:26-38. doi: 10.1016/j.gaitpost.2019.07.123. Epub 2019 Jul 2. Gait Posture. 2019. PMID: 31299501
Cited by
-
A deep learning approach to remotely assessing essential tremor with handwritten images.Sci Rep. 2025 Mar 28;15(1):10783. doi: 10.1038/s41598-025-94729-0. Sci Rep. 2025. PMID: 40155628 Free PMC article.
-
Assessing Parkinson's Rest Tremor from the Wrist with Accelerometry and Gyroscope Signals in Patients with Deep Brain Stimulation: An Observational Study.J Clin Med. 2025 Mar 18;14(6):2073. doi: 10.3390/jcm14062073. J Clin Med. 2025. PMID: 40142880 Free PMC article.
-
Better Understanding Rehabilitation of Motor Symptoms: Insights from the Use of Wearables.Pragmat Obs Res. 2025 Mar 19;16:67-93. doi: 10.2147/POR.S396198. eCollection 2025. Pragmat Obs Res. 2025. PMID: 40125472 Free PMC article. Review.
-
Empirical classification of fatigue-induced physiological tremor in robot-assisted manipulation tasks using BiLSTM-GRU network.Front Rehabil Sci. 2025 Jun 17;6:1474203. doi: 10.3389/fresc.2025.1474203. eCollection 2025. Front Rehabil Sci. 2025. PMID: 40626149 Free PMC article.
-
Evaluating Postural Sway in the Elderly Using Inertial Measurement Units: A Study on Center of Mass Measurements via Accelerometers and Gyroscopes.J Clin Med Res. 2025 Apr;17(4):200-207. doi: 10.14740/jocmr6184. Epub 2025 Apr 11. J Clin Med Res. 2025. PMID: 40322722 Free PMC article.
References
-
- Pourfar M. H. and Louis E. D., “Essential tremor,” in Current Therapy in Neurologic Disease, Johnson R. T., Griffin J. W., and McArthur J. C., Eds., 7th ed. Philadelphia, PA, USA: Mosby, 2006, pp. 288–292.