Assessing the time-to-removal of totally implantable venous access devices comparing valved-versus open-ended catheters in patients treated with chemotherapy
- PMID: 38205615
- DOI: 10.1177/11297298231223539
Assessing the time-to-removal of totally implantable venous access devices comparing valved-versus open-ended catheters in patients treated with chemotherapy
Abstract
Background: Totally IntraVenous Acess Devices (TIVAD) are used to have long-term bloodstream access. The catheter connected to the subcutaneous chamber may be valved (TIVAD-V) or open-ended (TIVAD-O). Infectious and occlusion complications require the removal of the TIVAD. We compared the two types of catheters (TIVAD-V and TIVAD-O) in terms of time-to-removal and complication rates.
Methods: A retrospective study of 636 patients treated for any malignancy using a TIVAD were included. TIVAD complication was defined as the occurrence of infection or occlusion requiring TIVAD removal. Risk factors of complications and time-to-removal of TIVAD were assessed by a Cox proportional hazard analysis.
Results: A total of 55 TIVADs (8.7%) were removed including 47 for infection and eight for occlusion in 54 months. There was no significant difference in the frequency of complications between TIVAD-V and TIVAD-O. There was no significant difference in time-to-removal between TIVAD-V and TIVAD-O (17.0 months, IQR [10.5-25.0] and 18.4 months, IQR [11.5-22.9], p = 0.345, respectively).
Conclusion: There was no difference between TIVAD with valved and open catheter in terms of complications and time-to-removal in patients treated by chemotherapy.
Keywords: Totally intravenous access device; chemotherapy; complications; open-ended catheter; time-to-removal; valved catheter.
Conflict of interest statement
Declaration of conflicting interestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Similar articles
-
Retrospective evaluation of totally implantable venous access port devices: early and late complications.J BUON. 2015 Jan-Feb;20(1):338-45. J BUON. 2015. PMID: 25778336
-
A comparison of infections and complications in central venous catheters in adults with solid tumours.J Vasc Access. 2015 Jan-Feb;16(1):38-41. doi: 10.5301/jva.5000300. Epub 2014 Sep 1. J Vasc Access. 2015. PMID: 25198809
-
Radiologic placement of totally implantable venous access devices: Outcomes and complications from a large oncology cohort.Ann Acad Med Singap. 2024 Dec 3;54(1):27-35. doi: 10.47102/annals-acadmedsg.2024166. Ann Acad Med Singap. 2024. PMID: 39886955
-
Infection of totally implantable venous access devices: A review of the literature.J Vasc Access. 2018 May;19(3):230-242. doi: 10.1177/1129729818758999. Epub 2018 Mar 7. J Vasc Access. 2018. PMID: 29512430 Review.
-
High success rate in salvage of catheter-related bloodstream infections due to Staphylococcus aureus, on behalf of project group of Italian society of nephrology.J Vasc Access. 2020 May;21(3):336-341. doi: 10.1177/1129729819875323. Epub 2019 Sep 12. J Vasc Access. 2020. PMID: 31512986 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical