Comparative Study
. 2025 Mar;26(2):447-454.
doi: 10.1177/11297298231223539. Epub 2024 Jan 11.

Assessing the time-to-removal of totally implantable venous access devices comparing valved-versus open-ended catheters in patients treated with chemotherapy

Affiliations
Comparative Study

Assessing the time-to-removal of totally implantable venous access devices comparing valved-versus open-ended catheters in patients treated with chemotherapy

Koceila Amroun et al. J Vasc Access. 2025 Mar.

Abstract

Background: Totally IntraVenous Acess Devices (TIVAD) are used to have long-term bloodstream access. The catheter connected to the subcutaneous chamber may be valved (TIVAD-V) or open-ended (TIVAD-O). Infectious and occlusion complications require the removal of the TIVAD. We compared the two types of catheters (TIVAD-V and TIVAD-O) in terms of time-to-removal and complication rates.

Methods: A retrospective study of 636 patients treated for any malignancy using a TIVAD were included. TIVAD complication was defined as the occurrence of infection or occlusion requiring TIVAD removal. Risk factors of complications and time-to-removal of TIVAD were assessed by a Cox proportional hazard analysis.

Results: A total of 55 TIVADs (8.7%) were removed including 47 for infection and eight for occlusion in 54 months. There was no significant difference in the frequency of complications between TIVAD-V and TIVAD-O. There was no significant difference in time-to-removal between TIVAD-V and TIVAD-O (17.0 months, IQR [10.5-25.0] and 18.4 months, IQR [11.5-22.9], p = 0.345, respectively).

Conclusion: There was no difference between TIVAD with valved and open catheter in terms of complications and time-to-removal in patients treated by chemotherapy.

Keywords: Totally intravenous access device; chemotherapy; complications; open-ended catheter; time-to-removal; valved catheter.

PubMed Disclaimer

Conflict of interest statement

Declaration of conflicting interestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.