Correlation of the transorbital ultrasonographic optic nerve sheath diameter with intracranial pressure measured intraoperatively in infants with hydrocephalus
- PMID: 38215445
- DOI: 10.3171/2023.12.PEDS23273
Correlation of the transorbital ultrasonographic optic nerve sheath diameter with intracranial pressure measured intraoperatively in infants with hydrocephalus
Abstract
Objective: Hydrocephalus is a highly significant global public health concern. In infants, it may be associated with a potentially deleterious increase in intracranial pressure (ICP). Currently, the gold standard for accurate monitoring of ICP is an intraventricular ICP monitor, but this method is invasive and expensive. Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) may provide a noninvasive and cost-effective alternative method for monitoring ICP. The goal of the study was to determine the extent of the correlation between ultrasonographic ONSD and ICP in infants.
Methods: A prospective observational study of 47 children with hydrocephalus aged ≤ 18 months was performed. The ONSD was measured with a transorbital ultrasound scan, while the intraventricular CSF opening pressure was assessed using a manometer during ventriculoperitoneal shunt insertion. Data were analyzed using SPSS software. The ONSD and ICP measurements were correlated, the receiver operating characteristic (ROC) curve was evaluated, and a sensitivity analysis was performed. Inferences were made using the 0.05 alpha level of significance.
Results: The mean age of the study cohort was 4.8 ± 4.3 months, and 93.6% of patients were infants. The mean ONSD was 4.5 ± 0.7 mm (range 2.9-6.0 mm), and the mean ICP was 19.9 ± 6.5 mm Hg (range 5.2-32.4 mm Hg). Both ONSD and ICP increased with increasing age. The Pearson correlation coefficient revealed a strong positive correlation between ONSD and ICP (r = 0.77, p < 0.001). The ONSD cutoff points were 3.2 mm, 4.0 mm, and 4.6 mm for patients with ICPs of 10 mm Hg, 15 mm Hg, and ≥ 20 mm Hg, respectively. The sensitivity of ONSD was 97.7% (area under the ROC curve 0.99), and for every 14.3-mm Hg increase in ICP, the ONSD increased by 1.0 mm holding age constant.
Conclusions: ONSD has a strong positive correlation with ICP. Correspondingly, ONSD is highly sensitive in estimating ICP.
Keywords: hydrocephalus; intracranial pressure; optic nerve sheath diameter; transorbital ultrasound.
Similar articles
-
Diagnostic accuracy of ultrasonographic optic nerve sheath diameter compared to invasive ICP monitoring for intracranial hypertension in pediatric patients.Pediatr Radiol. 2025 Jul;55(8):1669-1681. doi: 10.1007/s00247-025-06301-7. Epub 2025 Jun 17. Pediatr Radiol. 2025. PMID: 40526116
-
Bedside Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Assessing Increased Intracranial Pressure: An Observational Study.Cureus. 2025 Jun 16;17(6):e86163. doi: 10.7759/cureus.86163. eCollection 2025 Jun. Cureus. 2025. PMID: 40677488 Free PMC article.
-
Optic nerve sheath diameter correlates with both success and failure of hydrocephalus treatment in pediatric patients with pineal region lesions.Acta Neurochir (Wien). 2024 May 28;166(1):236. doi: 10.1007/s00701-024-06122-x. Acta Neurochir (Wien). 2024. PMID: 38805061
-
Effect of different positive end expiratory pressure levels on optic nerve sheath diameter in patients with or without midline shift who are undergoing supratentorial craniotomy.Acta Neurochir (Wien). 2024 Apr 15;166(1):177. doi: 10.1007/s00701-024-06067-1. Acta Neurochir (Wien). 2024. PMID: 38622368 Free PMC article.
-
The role of optic nerve sheath ultrasonography in increased intracranial pressure: A systematic review and meta analysis.J Neurol Sci. 2023 Nov 15;454:120853. doi: 10.1016/j.jns.2023.120853. Epub 2023 Oct 30. J Neurol Sci. 2023. PMID: 37925899
Cited by
-
Ultrasound-based radiomics and clinical factors-based nomogram for early intracranial hypertension detection in patients with decompressive craniotomy.Front Med Technol. 2025 Feb 5;7:1485244. doi: 10.3389/fmedt.2025.1485244. eCollection 2025. Front Med Technol. 2025. PMID: 39974430 Free PMC article.
-
Paediatric hydrocephalus.Nat Rev Dis Primers. 2024 May 16;10(1):35. doi: 10.1038/s41572-024-00519-9. Nat Rev Dis Primers. 2024. PMID: 38755194 Free PMC article. Review.
-
Diagnostic accuracy of ultrasonographic optic nerve sheath diameter compared to invasive ICP monitoring for intracranial hypertension in pediatric patients.Pediatr Radiol. 2025 Jul;55(8):1669-1681. doi: 10.1007/s00247-025-06301-7. Epub 2025 Jun 17. Pediatr Radiol. 2025. PMID: 40526116
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical