. 2024 Apr;47(2):102105.
doi: 10.1016/j.clae.2023.102105. Epub 2024 Jan 11.

Multifocal contact lens success predictability

Affiliations
Free article

Multifocal contact lens success predictability

Percy Lazon de la Jara et al. Cont Lens Anterior Eye. 2024 Apr.
Free article

Abstract

Purpose: The current multi-study analysis combined data from three studies to quantify the relationship between the initial reaction to soft multifocal contact lens (MFCL) design types at dispensing and evaluate the predictability of overall vision satisfaction (OVS) and intention to purchase (ITP) after 1 week of wear.

Method: Three prospective studies tested MFCLs over 1-week of wear following the same protocol, using a range of potentially predictive ratings at dispensing, and both OVS and ITP at 1-week as an indicator acceptance level. In each study, two of MyDay® multifocal, clariti® 1 day multifocal, Biofinity® multifocal (worn as a daily disposable lens) or 1 DAY ACUVUE® MOIST MULTIFOCAL were dispensed for 1-week of daily wear. OVS was recorded on a 100-point VAS and ITP on a 5-point LIKERT scale. Fourteen possible predictors were entered in the statistical model, and predictability was assessed using Chi-square Automatic Interaction Detector (CHAID) statistical test.

Results: A total of 210 participants (152 female & 58 male; 53.9 ± 6.5 years, range 41-71 years), representing 420 MFCL fits, equally distributed between emergent n = 65, established n = 70 and advanced n = 75 presbyopes, completed the studies. OVS on dispensing was the predictor of both OVS (p < 0.001) and ITP (p < 0.001) at 1-week. For OVS predictability, 70.8 % with OVS at dispensing > 91 points reported good OVS at 1-week and 73.4 % with OVS on dispensing ≤ 80 points reported poor OVS at 1-week. For ITP predictability, 74.6 % with OVS at dispensing > 94 points reported a positive ITP at 1-week and 65.9 % with OVS on dispensing ≤ 63 points reported negative ITP at 1-week.

Conclusion: Overall vision satisfaction at the time of dispensing MFCLs is a powerful indicator of both OVS and ITP after 1-week of wear. Initial patient subjective assessments provide a clinically useful indicator of the likeliness of success.

Keywords: Intention to purchase; Multifocal contact lens; Predictability; Vision satisfaction.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.