Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Mar;79(3):213-220.
doi: 10.1016/j.crad.2023.12.010. Epub 2024 Jan 3.

Practical use of the central venous access port for contrast-enhanced CT: comparison with peripheral intravenous access regarding enhancement and safety

Affiliations

Practical use of the central venous access port for contrast-enhanced CT: comparison with peripheral intravenous access regarding enhancement and safety

H Washio et al. Clin Radiol. 2024 Mar.

Abstract

Aim: To evaluate the efficacy of using the central venous (CV) port compared with peripheral intravenous access for contrast-material injection for contrast enhancement during the portal venous phase.

Materials and methods: Patients were divided into three groups: CV delay, CV routine, and peripheral access (PA) groups. Patients in the CV delay group underwent injection in the arm-down position with an additional delay, while those in the CV routine and PA groups underwent injections with the routine injection protocol for portal venous phase imaging. Contrast enhancement was evaluated by measuring the mean radiodensity (Hounsfield units) values for the aortic arch, abdominal aorta, inferior vena cava, portal vein, and spleen. The peak injection pressure was recorded and compared among the three groups.

Results: No complications related to power injection were observed during 119 contrast-material injections performed using the CV port device. The CV delay group showed significantly lower radiodensity values than the PA group (165.7 ± 20.1 versus 181 ± 19 HU [p<0.01] for the portal vein); however, no significant differences in mean radiodensity values were observed between the CV routine and PA groups (p>0.05). The median peak injection pressure was 73.5, 67, and 47 psi in the CV delay, CV routine, and PA groups, respectively (p<0.01).

Conclusion: The CV port can be used for safe contrast-material injection while maintaining contrast enhancement on portal venous phase comparable to that achieved with peripheral intravenous access.