Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2024;14(1):67-73.
doi: 10.1159/000535575. Epub 2024 Jan 13.

Hemoadsorption Contribution in Failing Fontan Pediatric Heart Transplantation

Affiliations
Free article
Case Reports

Hemoadsorption Contribution in Failing Fontan Pediatric Heart Transplantation

Carlo Pace Napoleone et al. Cardiorenal Med. 2024.
Free article

Abstract

Introduction: A systemic inflammatory response is triggered in patients undergoing cardiothoracic surgery with cardiopulmonary bypass (CPB). This response is particularly evident in pediatric patients, especially those of low weight and after undergoing long CPB, and can severely impair the surgical result. Adsorptive blood purification techniques have been proposed to limit this systemic inflammatory response. To test its efficacy, we added the hemoadsorption filter Jafron HA 380 to CPB in a much compromised pediatric patient who underwent heart transplantation.

Methods: A 10-year-old single ventricle patient previously treated with Fontan operation was listed for heart transplantation due to the evidence of failing Fontan condition. He experienced many episodes of cardiac arrest and underwent heart transplantation in much compromised general and hemodynamic conditions. The hemoadsorption filter Jafron HA 380 was used for all the duration of CPB, and the inflammatory biomarker interleukin 6 (IL-6) was assayed.

Results: Postoperative outcome was uneventful and comparable to that of elective pediatric heart transplantation. IL-6 levels showed an impressive postoperative reduction, and after 2 days, the IL-6 level was comparable with a typical uneventful post-transplant course.

Conclusions: The use of hemoadsorption filter can contribute to improve the pediatric transplant results, especially in very high-risk patients.

Keywords: Cardiopulmonary bypass inflammatory response; Fontan operation; Hemoadsorption; Inflammatory mediators; Pediatric heart transplantation.

PubMed Disclaimer

Publication types