. 2023 Dec 16;15(12):e50615.
doi: 10.7759/cureus.50615. eCollection 2023 Dec.

Impact of Invisalign G-series Updates on Improving Predicted Outcomes: A Retrospective Study

Affiliations

Impact of Invisalign G-series Updates on Improving Predicted Outcomes: A Retrospective Study

Eman Fatani et al. Cureus. .

Abstract

Background: Understanding the real-world implications of periodic changes to orthodontic appliances can provide valuable insights for future treatment strategies and patient outcomes. This study aimed to investigate the impact of the latest updates added to the G7 and G8 Invisalign series on actual versus predicted outcomes and the percentage accuracy of the treatment.

Method: This retrospective study was conducted in private orthodontic practices in Riyadh, Saudi Arabia. Orthodontists carried out Invisalign® treatment using the latest updates added to the G7 and G8 Invisalign series. The study group comprised patients with different malocclusion types who received non-extraction Invisalign treatment. The Invisalign treatment plan was provided by the ClinChecks program (Invisalign, San Jose, United States) for patients treated throughout the years (2016-2022). Different dimensions were assessed to record predicted and actual treatment outcomes with the aid of iTero® (Align Technology, San Jose, United States) and ClinCheck® (Invisalign, San Jose, United States). The percentage accuracy was determined using the formula (100%-((Predicted-Actual)/Predicted) *100%).

Results: A total of 108 patients (male = 34 (31.5%) and female = 74 (68.5%)) treated with Invisalign G7 and G8 series were considered in this study. The overall mean and standard deviation values of vertical distance (2.91±1.42), intermolar distance in the lower arch (52.68±3.15), overjet (2.71±1.06), and inter-incisal angle (138.24±12.18) were higher than the predicted model. However, the predicted model showed higher mean and standard deviation values for intercanine distances in the upper (36.94±1.57) and lower arches (28.48±1.40) and upper intermolar distances (57.21±2.91). The G7 versus G8 intercanine distance in lower (61.28±47.67 vs. 80.51±38.32), intermolar distance in upper (61.72±47.67 vs. 69.95±44.11), and intermolar distance in lower (100.68±3.80 vs. 100.89±2.52) were relatively higher in the G8 series than the G7. The accuracy percentage was higher with the G8 series than with the G7 regarding the intercanine distance in the upper arch. In contrast, the G7 series showed a higher mean percentage accuracy of vertical distance (91.11±84.83 vs. 76.76±65.45), overjet (58.44±35.17 vs. 53.71±45.87), and inter-incisal angle (34.47±44.06 vs. 27.53±37.98) than the G8 series.

Conclusion: The percentage accuracy of aligner therapy administered using the Invisalign G7 and G8 series demonstrated no significant variation.

Keywords: achieved outcome; invisalign g-series; orthodontic treatment; percentage accuracy; predicted outcome.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Graphical representation of correlation and percentage accuracy of predicted and achieved variables of G7 and G8 Invisalign series
Figure 2
Figure 2. Graphical representation of the percentage accuracy of variables between G7 and G8 Invisalign series

References

    1. Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review. Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL. Angle Orthod. 2015;85:881–889. - PMC - PubMed
    1. A systematic review of the accuracy and efficiency of dental movements with Invisalign®. Galan-Lopez L, Barcia-Gonzalez J, Plasencia E. Korean J Orthod. 2019;49:140–149. - PMC - PubMed
    1. Evaluation of the reliability, reproducibility and validity of digital orthodontic measurements based on various digital models among young patients. Park SH, Byun SH, Oh SH, Lee HL, Kim JW, Yang BE, Park IY. J Clin Med. 2020;9:2728. - PMC - PubMed
    1. Mackay MM, Bethell R, Epstein J. https://storagy-itero-production-eu.s3.amazonaws.com/download/en/iTero-S... Acquisition of iTero Element Intraoral Scanners: Three-Year Examination of Practice Volume Changes and Economic Impact. 2019
    1. Comparison of digital intraoral scanners and alginate impressions: time and patient satisfaction. Burzynski JA, Firestone AR, Beck FM, Fields HW Jr, Deguchi T. Am J Orthod Dentofacial Orthop. 2018;153:534–541. - PubMed

LinkOut - more resources