Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2024 Jan-Mar;27(1):101452.
doi: 10.1016/j.jocd.2023.101452. Epub 2023 Dec 5.

Clinical Use of Trabecular Bone Score: The 2023 ISCD Official Positions

Affiliations
Review

Clinical Use of Trabecular Bone Score: The 2023 ISCD Official Positions

Heenam Goel et al. J Clin Densitom. 2024 Jan-Mar.

Abstract

Osteoporosis can currently be diagnosed by applying the WHO classification to bone mineral density (BMD) assessed by dual-energy x-ray absorptiometry (DXA). However, skeletal factors other than BMD contribute to bone strength and fracture risk. Lumbar spine TBS, a grey-level texture measure which is derived from DXA images has been extensively studied, enhances fracture prediction independent of BMD and can be used to adjust fracture probability from FRAX® to improve risk stratification. The purpose of this International Society for Clinical Densitometry task force was to review the existing evidence and develop recommendations to assist clinicians regarding when and how to perform, report and utilize TBS. Our review concluded that TBS is most likely to alter clinical management in patients aged ≥ 40 years who are close to the pharmacologic intervention threshold by FRAX. The TBS value from L1-L4 vertebral levels, without vertebral exclusions, should be used to calculate adjusted FRAX probabilities. L1-L4 vertebral levels can be used in the presence of degenerative changes and lumbar compression fractures. It is recommended not to report TBS if extreme structural or pathological artifacts are present. Monitoring and reporting TBS change is unlikely to be helpful with the current version of the TBS algorithm. The next version of TBS software will include an adjustment based upon directly measured tissue thickness. This is expected to improve performance and address some of the technical factors that affect the current algorithm which may require modifications to these Official Positions as experience is acquired with this new algorithm.

Keywords: None.

PubMed Disclaimer

MeSH terms

LinkOut - more resources