. 2024 Apr:172:106119.
doi: 10.1016/j.neunet.2024.106119. Epub 2024 Jan 9.

Optimization of epilepsy detection method based on dynamic EEG channel screening

Affiliations

Optimization of epilepsy detection method based on dynamic EEG channel screening

Yuebin Song et al. Neural Netw. 2024 Apr.

Abstract

To decrease the interference in the process of epileptic feature extraction caused by insufficient detection capability in partial channels of focal epilepsy, this paper proposes a novel epilepsy detection method based on dynamic electroencephalogram (EEG) channel screening. This method not only extracts more effective epilepsy features but also finds common features among different epilepsy subjects, providing an effective approach and theoretical support for across-subject epilepsy detection in clinical scenarios. Firstly, we use the Refine Composite Multiscale Dispersion Entropy (RCMDE) to measure the complexity of EEG signals between normal and seizure states and realize the dynamic EEG channel screening among different subjects, which can enhance the capability of feature extraction and the robustness of epilepsy detection. Subsequently, we discover common epilepsy features in 3-15 Hz among different subjects by the screened EEG channels. By this finding, we construct the Residual Convolutional Long Short-Term Memory (ResCon-LSTM) neural network to accomplish across-subject epilepsy detection. The experiment results on the CHB-MIT dataset indicate that the highest accuracy of epilepsy detection in the single-subject experiment is 98.523 %, improved by 5.298 % compared with non-channel screening. In the across-subject experiment, the average accuracy is 96.596 %. Therefore, this method could be effectively applied to different subjects by dynamically screening optimal channels and keep a good detection performance.

Keywords: Dynamic channel screening; Epilepsy detection; RCMDE; ResCon-LSTM neural network; STFT.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.