Incidence of 'dry tap' on bone marrow aspirations in lymphomas and carcinomas. Diagnostic value of the small material in the needle
- PMID: 382344
Incidence of 'dry tap' on bone marrow aspirations in lymphomas and carcinomas. Diagnostic value of the small material in the needle
Abstract
Of 2907 bone marrow aspirations in patients with various malignancies, 192 or 6.6% exhibited 'dry tap'. In about 80% of the 'dry tap' there was material present inside the bone marrow needle which gave smears useful for evaluation of the bone marrow cytology. About 23% displayed normal cytology. Bone marrow involvement could be diagnosed in 13 out of 55 'dry tap' in Hodgkin's disease, 41 out of 46 in chronic lymphocytic leukaemia and lymphosarcoma, 6 out of 20 in reticulum cell sarcoma, 6 out of 9 in myelomatosis and 20 out of 45 in carcinoma. In a material of 174 aspirations with tumour cells in the bone marrow aspirate, the highest incidence of 'dry tap' was found in patients with Hodgkin's disease and patients with carcinoma, the lowest incidence in patients with multiple myeloma.
Similar articles
-
Histopathological trephine biopsy findings in cases of 'dry tap' bone marrow aspirations.Appl Pathol. 1984;2(5):264-71. Appl Pathol. 1984. PMID: 6545669
-
Bone marrow and peripheral blood involvement in non-Hodgkin's lymphomas.Geriatrics. 1975 Oct;30(10):75-80. Geriatrics. 1975. PMID: 1098960 No abstract available.
-
[Advances of bone marrow biopsy pathology in diagnosing lymphoma bone marrow involvement].Ai Zheng. 2005 Nov;24(11):1416-20. Ai Zheng. 2005. PMID: 16552975 Review. Chinese.
-
[Jamshidi biopsy in clinical hematology. Method, indications and results of over 1,000 completed biopsies with special reference to chronic myeloproliferative diseases].Wien Med Wochenschr Suppl. 1986;100:1-24. Wien Med Wochenschr Suppl. 1986. PMID: 3471009 German.
-
Bone marrow in malignant lymphoma.Hematol Oncol Clin North Am. 1988 Dec;2(4):617-35. Hematol Oncol Clin North Am. 1988. PMID: 3065322 Review.
Cited by
-
Diagnostic value of preparing bone marrow smears from the small amount of material left within the aspiration needle following a dry tap.Clin Case Rep. 2018 Oct 26;6(12):2427-2430. doi: 10.1002/ccr3.1892. eCollection 2018 Dec. Clin Case Rep. 2018. PMID: 30564342 Free PMC article.
-
A pathologist's perspective on bone marrow aspiration and biopsy: I. Performing a bone marrow examination.J Clin Lab Anal. 2004;18(2):70-90. doi: 10.1002/jcla.20008. J Clin Lab Anal. 2004. PMID: 15065211 Free PMC article. Review.
-
Systematic comparison of donor chimerism in peripheral blood and bone marrow after hematopoietic stem cell transplantation.Blood Cancer J. 2017 Jun 2;7(6):e566. doi: 10.1038/bcj.2017.42. Blood Cancer J. 2017. PMID: 28574489 Free PMC article. No abstract available.
MeSH terms
LinkOut - more resources
Miscellaneous