In vitro evaluation of wear resistance, microhardness and superficial roughness of different fissure sealants after aging
- PMID: 38239154
- DOI: 10.22514/jocpd.2024.005
In vitro evaluation of wear resistance, microhardness and superficial roughness of different fissure sealants after aging
Abstract
The aim of this study was to compare the aging effects on wear, surface roughness and microhardness of fissure sealants having varying contents. Four fissure sealant types were used in the study: Aegis (Bosworth, USA) (Group A), Beautisealant (Shofu, Japan) (Group B), Clinpro (3M, USA) (Group C), and Ultraseal XT/Hydro (Ultradent, USA) (Group U). Hundred disc-shaped specimens (5 mm diameter/3 mm width) were designed according to the manufacturer's instructions and assigned for microhardness/Vickers Hardness (VHN), surface roughness, and wear tests. Thermocycling (10,000 times/5-55 °C ± 2 °C/20 s) and chewing simulator (75,000 times/49 N) were applied as the aging procedures. Measurements were made before and after the aging procedures. The specimens were examined by Scanning Electrone Microscopy (SEM). Data was statistically analyzed through Kruskal Wallis, Wilcoxon and Welch tests. The highest and the lowest changes in mean microhardness values were obtained for Group U (9.88 ± 1.46) and Group A (4.40 ± 0.46), respectively; and a significant difference (p < 0.001) was found between the mean changes in microhardness numbers (U > B > C > A). The median roughness values had no significant difference; the surface roughness had the highest mean differences in Groups U and C (U = C > A > B). Significant difference was found between the mean changes in wear/weight values (p < 0.001); the highest and the lowest mean weight losses were recorded in Group U (0.0097 ± 0.0003 gr), and Group C (0.0041 ± 0.0006 gr), respectively (U > B > A > C). The highest physical changes were determined in Group U after the aging procedures. It is concluded that the aging procedures affect physical structures of all test materials with varying degrees, however Ultraseal XT/Hydro is the most affected. The individual treatment needs and material properties must be considered to select a fissure sealant material.
Keywords: Aging procedure; Fissure sealant; Microhardness; Roughness; Wear.
©2024 The Author(s). Published by MRE Press.
Conflict of interest statement
The authors declare no conflict of interest.
Similar articles
-
Effect of Aging on the Microhardness of Different Resin-based Fluoride-releasing Fissure Sealants: An In Vitro Study.J Contemp Dent Pract. 2021 Oct 1;22(10):1144-1149. J Contemp Dent Pract. 2021. PMID: 35197382
-
Conversion degree, microhardness, microleakage and fluoride release of different fissure sealants.J Mech Behav Biomed Mater. 2010 Nov;3(8):594-9. doi: 10.1016/j.jmbbm.2010.07.008. Epub 2010 Jul 27. J Mech Behav Biomed Mater. 2010. PMID: 20826365
-
Influence of incorporation of nanostructured silver vanadate decorated with silver nanoparticles on roughness, microhardness, and color change of pit and fissure sealants.Heliyon. 2024 Feb 6;10(4):e25525. doi: 10.1016/j.heliyon.2024.e25525. eCollection 2024 Feb 29. Heliyon. 2024. PMID: 38384570 Free PMC article.
-
Effect of curing method and curing time on the microhardness and wear of pit and fissure sealants.Dent Mater. 2002 Mar;18(2):120-7. doi: 10.1016/s0109-5641(01)00030-6. Dent Mater. 2002. PMID: 11755590
-
Characterisation and microleakage of a new hydrophilic fissure sealant - UltraSeal XT® hydro™.J Appl Oral Sci. 2016 Jul-Aug;24(4):344-51. doi: 10.1590/1678-775720160010. J Appl Oral Sci. 2016. PMID: 27556205 Free PMC article.
Cited by
-
Degradation and ultrastructural changes of resin-based pit and fissure sealants under simulated chewing conditions.BMC Oral Health. 2025 Feb 4;25(1):185. doi: 10.1186/s12903-025-05570-w. BMC Oral Health. 2025. PMID: 39905424 Free PMC article.
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources