Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2024 Apr:80:154400.
doi: 10.1016/j.jcrc.2023.154400.

Early prediction of sepsis in intensive care patients using the machine learning algorithm NAVOY® Sepsis, a prospective randomized clinical validation study

Affiliations
Free article
Randomized Controlled Trial

Early prediction of sepsis in intensive care patients using the machine learning algorithm NAVOY® Sepsis, a prospective randomized clinical validation study

Inger Persson et al. J Crit Care. 2024 Apr.
Free article

Abstract

Purpose: To prospectively validate, in an ICU setting, the prognostic accuracy of the sepsis prediction algorithm NAVOY® Sepsis which uses 4 h of input for routinely collected vital parameters, blood gas values, and lab values.

Materials and methods: Patients 18 years or older admitted to the ICU at Skåne University Hospital Malmö from December 2020 to September 2021 were recruited in the study. A total of 304 patients were randomized into one of two groups: Algorithm group with active sepsis alerts, or Standard of care. NAVOY® Sepsis made silent predictions in the Standard of care group, in order to evaluate its performance without disturbing the outcome. The study was blinded, i.e., study personnel did not know to which group patients were randomized. The healthcare provider followed standard practices in assessing possible development of sepsis and intervening accordingly. The patients were followed-up in the study until ICU discharge.

Results: NAVOY® Sepsis could predict the development of sepsis, according to the Sepsis-3 criteria, three hours before sepsis onset with high performance: accuracy 0.79; sensitivity 0.80; and specificity 0.78.

Conclusions: The accuracy, sensitivity, and specificity were all high, validating the prognostic accuracy of NAVOY® Sepsis in an ICU setting, including Covid-19 patients.

Trial registration: ClinicalTrials.gov NCT04570618.

Keywords: Early detection; Intensive care unit; Machine learning; Prediction; Sepsis; Software as a medical device.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest David Becedas and Inger Persson are shareholders of AlgoDx AB, and Andreas Macura has received stock options from AlgoDx AB.

Publication types

Associated data