Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1979 May;81(2):275-300.
doi: 10.1083/jcb.81.2.275.

Synaptic vesicle exocytosis captured by quick freezing and correlated with quantal transmitter release

Synaptic vesicle exocytosis captured by quick freezing and correlated with quantal transmitter release

J E Heuser et al. J Cell Biol. 1979 May.

Abstract

We describe the design and operation of a machine that freezes biological tissues by contact with a cold metal block, which incorporates a timing circuit that stimulates frog neuromuscular junctions in the last few milliseconds before thay are frozen. We show freeze-fracture replicas of nerve terminals frozen during transmitter discharge, which display synpatic vesicles caught in the act of exocytosis. We use 4-aminopyridine (4-AP) to increase the number of transmitter quanta discharged with each nerve impulse, and show that the number of exocytotic vesicles caught by quick-freezing increases commensurately, indicating that one vesicle undergoes exocytosis for each quantum that is discharged. We perform statistical analyses on the spatial distribution of synaptic vesicle discharge sites along the "active zones" that mark the secretory regions of these nerves, and show that individual vesicles fuse with the plasma membrane independent of one another, as expected from physiological demonstrations that quanta are discharged independently. Thus, the utility of quick-freezing as a technique to capture biological processes as evanescent as synaptic transmission has been established. An appendix describes a new capacitance method to measure freezing rates, which shows that the "temporal resolution" of our quick-freezing technique is 2 ms or better.

PubMed Disclaimer

References

    1. Cold Spring Harb Symp Quant Biol. 1976;40:17-24 - PubMed
    1. J Physiol. 1976 Jun;258(1):145-55 - PubMed
    1. J Neurocytol. 1976 Dec;5(6):691-718 - PubMed
    1. J Physiol. 1954 May 28;124(2):370-84 - PubMed
    1. J Physiol. 1960 Jan;150:134-44 - PubMed

Publication types

MeSH terms