Occupational allergic contact dermatitis from 2-butyl-1,2-benzisothiazol-3-one in cutting fluids: A case series
- PMID: 38263711
- DOI: 10.1111/cod.14503
Occupational allergic contact dermatitis from 2-butyl-1,2-benzisothiazol-3-one in cutting fluids: A case series
Keywords: 2‐butyl‐1,2‐benzisothiazolin‐3‐one; 2‐n‐butyl‐benzo[d]isothiazol‐3‐one; BBIT; CAS no. 4299‐07‐4; contact dermatitis; isothiazolinone; metalworking fluid; occupational.
Similar articles
-
Contact dermatitis from 2-butyl-1,2-benzisothiazolin-3-one in a cutting fluid.Contact Dermatitis. 2020 Nov;83(5):414-415. doi: 10.1111/cod.13624. Epub 2020 Jun 22. Contact Dermatitis. 2020. PMID: 32462655 No abstract available.
-
Occupational contact dermatitis caused by N-butyl-1,2-benzisothiazolin-3-one in a cutting fluid.Contact Dermatitis. 2015 Jul;73(1):60-2. doi: 10.1111/cod.12391. Epub 2015 Apr 16. Contact Dermatitis. 2015. PMID: 25880799 No abstract available.
-
Occupational allergic contact dermatitis caused by 2-butyl-1,2-benzisothiazol-3(2H)-one in a metalworker.Contact Dermatitis. 2019 Dec;81(6):463-465. doi: 10.1111/cod.13366. Epub 2019 Aug 14. Contact Dermatitis. 2019. PMID: 31373021 No abstract available.
-
Occupational cobalt sensitivity in 2 hard-metal press operators.Contact Dermatitis. 2002 Oct;47(4):239-40. doi: 10.1034/j.1600-0536.2002.470414_1.x. Contact Dermatitis. 2002. PMID: 12492529 Review. No abstract available.
-
[Contact dermatitis. II].Hautarzt. 1996 Dec;47(12):945-61; quiz 958-60. doi: 10.1007/BF03355108. Hautarzt. 1996. PMID: 9081946 Review. German. No abstract available.
Cited by
-
Selective Oxidation of Benzo[d]isothiazol-3(2H)-Ones Enabled by Selectfluor.Molecules. 2024 Aug 17;29(16):3899. doi: 10.3390/molecules29163899. Molecules. 2024. PMID: 39202979 Free PMC article.
-
Recent Advances in the Synthesis of Benzo[d]isothiazol-3(2H)-One and Benzo[e][1,3]Thiazin-4-One Derivatives.Molecules. 2025 May 9;30(10):2099. doi: 10.3390/molecules30102099. Molecules. 2025. PMID: 40430272 Free PMC article. Review.
References
REFERENCES
-
- Dahlin J, Isaksson M. Occupational contact dermatitis caused by N‐butyl‐1,2‐benzisothiazolin‐3‐one in a cutting fluid. Contact Dermatitis. 2015;73(1):60‐62. doi:10.1111/cod.12391
-
- Jacobs MC, Herman A. Contact dermatitis from 2‐butyl‐1,2‐benzisothiazolin‐3‐one in a cutting fluid. Contact Dermatitis. 2020;83(5):414‐415. doi:10.1111/cod.13624
-
- Foti C, Romita P, Stufano A, et al. Occupational allergic contact dermatitis caused by 2‐butyl‐1,2‐benzisothiazol‐3(2H)‐one in a metalworker. Contact Dermatitis. 2019;81(6):463‐465. doi:10.1111/cod.13366
-
- Mahler V, Nast A, Bauer A, et al. S3 guidelines: Epicutaneous patch testing with contact allergens and drugs—short version, part 1. J Dtsch Dermatol Ges. 2019;17(10):1076‐1093. doi:10.1111/ddg.13956
-
- Mahler V, Nast A, Bauer A, et al. S3 guidelines: Epicutaneous patch testing with contact allergens and drugs—short version, part 2. J Dtsch Dermatol Ges. 2019;17(11):1187‐1207. doi:10.1111/ddg.13971
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources