Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd
- PMID: 38269008
- PMCID: PMC10804427
- DOI: 10.22099/IJVR.2023.47029.6770
Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd
Abstract
Background: With the increasing use of cementless total hip arthroplasty (THA), stem subsidence has emerged as one of the primary complications. Although electron beam melting (EBM)-manufactured stems have been demonstrated to prevent subsidence, there has been limited investigation into the comparative biomechanical impact of collarless and collared EBM cementless stems on stem subsidence in veterinary medicine.
Aims: This study aimed to compare the stem implant resistance and failure mechanical properties between collarless and collared EBM-manufactured stems.
Methods: Seven pairs of femurs were harvested from canine cadavers. In each pair of femurs, the left femur was implanted with a collarless, and the right femur with a same-sized collared cementless stem. Specimen constructs were mounted to the loading frame of a testing machine and load was transferred to the femoral stem parallel to the longitudinal axis of the femur until the stem subsided 5 mm. Load and stem displacement data acquired during the tests were used to generate load-displacement curves and obtain stiffness, yield, and failure data for each specimen construct. Yield and failure energies were calculated as the areas under the load-displacement curves to the respective points. The effects of implant type and load during subsidence were analyzed using paired t-tests.
Results: The yield and failure loads for the collared stems were approximately 40% greater than for the collarless stems (156.39 ± 43.63 kgf vs. 112.01 ± 59.83 kgf, P<0.05).
Conclusion: This study supported the advantages of collared EBM stems, including subsidence prevention and better initial stability for early osteointegration.
Keywords: Biomechanical evaluation; Canine cadaver; Cementless; Load; Total hip arthroplasty.
Conflict of interest statement
The authors declare no conflict of interest.
Figures


Similar articles
-
Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.Int Orthop. 2018 Jan;42(1):49-57. doi: 10.1007/s00264-017-3524-0. Epub 2017 Jun 7. Int Orthop. 2018. PMID: 28589313
-
Use of an Electron Beam Melting Manufactured Titanium Collared Cementless Femoral Stem to Resist Subsidence After Canine Total Hip Replacement.Vet Surg. 2015 Oct;44(7):883-94. doi: 10.1111/vsu.12353. Epub 2015 Jul 1. Vet Surg. 2015. PMID: 26138323
-
Loosely implanted cementless stems may become rotationally stable after loading.Clin Orthop Relat Res. 2014 Jul;472(7):2231-6. doi: 10.1007/s11999-014-3577-y. Epub 2014 Mar 25. Clin Orthop Relat Res. 2014. PMID: 24664196 Free PMC article.
-
Comparative outcomes between collared versus collarless and short versus long stem of direct anterior approach total hip arthroplasty: a systematic review and indirect meta-analysis.Eur J Orthop Surg Traumatol. 2019 Dec;29(8):1693-1704. doi: 10.1007/s00590-019-02516-1. Epub 2019 Jul 30. Eur J Orthop Surg Traumatol. 2019. PMID: 31363848
-
Slightly reduced early subsidence with similar outcomes and complications rate in collared stems - A systematic review of randomized clinical trials.J Orthop. 2024 Jan 26;50:170-176. doi: 10.1016/j.jor.2024.01.013. eCollection 2024 Apr. J Orthop. 2024. PMID: 38328796 Free PMC article. Review.
References
-
- Aspenberg P, Goodman S, Toksvig-Larsen S, Albrektsson T. Intermittent micromotion inhibits bone ingrowth: titanium implants in rabbits. Acta Orthop. Scand. 1992;63:141–145. - PubMed
-
- Barrack RL, Jasty M, Bragdon C, Haire T, Harris WH. Thigh pain despite bone ingrowth into uncemented femoral stems. J. Bone. Joint. Surg. Br. 1992;74:507–510. - PubMed
-
- Cross AR, Newell SM, Chambers JN, Shultz KB, Kubilis PS. Acetabular component orientation as an indicator of implant luxation in cemented total hip arthroplasty. Vet. Surg. 2000;29:517–523. - PubMed
-
- Demey G, Fary C, Lustig S, Neyret P, si Selmi TA. Does a collar improve the immediate stability of uncemented femoral hip stems in total hip arthroplasty? A bilateral comparative cadaver study. J. Arthroplasty. 2011;26:1549–1555. - PubMed
LinkOut - more resources