Efficacy, Feasibility, and Safety of the X-Tack Endoscopic HeliX Tacking System: A Multicenter Experience
- PMID: 38277501
- DOI: 10.1097/MCG.0000000000001977
Efficacy, Feasibility, and Safety of the X-Tack Endoscopic HeliX Tacking System: A Multicenter Experience
Abstract
Background and aims: The application of endoscopic suturing has revolutionized defect closures. Conventional over-the-scope suturing necessitates removal of the scope, placement of the device, and reinsertion. A single channel, single sequence, through-the-scope suturing device has been developed to improve this process. This study aims to describe the efficacy, feasibility, and safety of a through-the-scope suturing device for gastrointestinal defect closure.
Methods: This was a retrospective multicenter study involving 9 centers of consecutive adult patients who underwent suturing using the X-Tack Endoscopic HeliX Tacking System (Apollo Endosurgery). The primary outcomes were technical success and long-term clinical success. Secondary outcomes included adverse events, recurrence, and reintervention rates.
Results: In all, 56 patients (mean age 53.8, 33 women) were included. Suturing indications included fistula repair (n=22), leak repair (n=7), polypectomy defect closure (n=12), peroral endoscopic myotomy (POEM) site closure (n=7), perforation repair (n=6), and ulcers (n=2). Patients were followed at a mean duration of 74 days. Overall technical and long-term clinical success rates were 92.9% and 75%, respectively. Both technical and clinical success rates were 100% for polypectomies, POEM-site closures, and ulcers. Success rates were lower for the repair of fistulas (95.5% technical, 54.5% clinical), leaks (57.1%, 28.6%), and perforations (100%, 66.7%). No immediate adverse events were noted.
Conclusion: This novel, through-the-scope endoscopic suturing system, is a safe and feasible method to repair defects that are ≤3 cm. The efficacy of this device may be better suited for superficial defects as opposed to full-thickness defects. Larger defects will need more sutures and probably a double closure technique to provide a reinforcement layer.
Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
References
-
- de Moura DTH, Sachdev AH, Thompson CC. Endoscopic full thickness defects and closure techniques. Curr Treat Options Gastroenterol. 2018;16:386–405.
-
- Zhang LY, Ngamruengphong S, Khashab MA. Closing the gap: Applications, tips, and tricks for a novel through-the-scope suturing device. Am J Gastroenterol. 2022;117:1022–1027.
-
- Kirschniak A, Subotova N, Zieker D, et al. The over-the-scope clip (OTSC) for the treatment of gastrointestinal bleeding, perforations, and fistulas. Surg Endosc. 2011;25:2901–2905.
-
- Bi D, Zhang LY, Alqaisieh M, et al. Novel through-the-scope suture closure of colonic EMR defects (with video). Gastrointest Endosc. 2023;98:122–129.
-
- Almario JA, Zhang LY, Cohen J, et al. Through-the-scope suture closure of nonampullary duodenal endoscopic mucosal resection defects: a retrospective multicenter cohort study. Endoscopy. 2023;55:865–870.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
