Accuracy of 24 h ambulatory blood pressure recordings for diagnosing high 44 h blood pressure in hemodialysis: a diagnostic test study
- PMID: 38291259
- DOI: 10.1038/s41440-024-01584-z
Accuracy of 24 h ambulatory blood pressure recordings for diagnosing high 44 h blood pressure in hemodialysis: a diagnostic test study
Abstract
Hypertension is highly prevalent in hemodialysis patients. Ambulatory-BP-monitoring(ABPM) during the 44 h interdialytic interval is recommended for hypertension diagnosis and management in these subjects. This study assessed the diagnostic accuracy of fixed 24 h ABPM recordings with 44 h BP in hemodialysis patients. 242 Greek hemodialysis patients that underwent valid 48 h ABPM(Mobil-O-Graph NG device) were included in the analysis. We used 44 h BP as reference method and tested the accuracy of the following BP metrics: 1st 24 h without HD period (20 h-1st), 1st 24 h including HD period (24 h-1st) and 2nd 24 h(24 h-2nd). All studied metrics showed strong correlations with 44 h SBP/DBP (20 h-1st: r = 0.973/0.978, 24 h-1st: r = 0.964/0.972 and 24 h-2nd: r = 0.978/0.977, respectively). In Bland-Altman analysis, small between-method differences (-1.70, -1.19 and +1.45 mmHg) with good 95% limits-of agreement([-10.83 to 7.43], [-11.12 to 8.74] and [-6.33 to 9.23] mmHg, respectively) for 20 h-1st, 24 h-1st and 24 h-2nd SBP were observed. The sensitivity/specificity and κ-statistic for diagnosing 44 h SBP ≥ 130 mmHg were high for 20 h-1st SBP(87.2%/96.0%, κ-statistic = 0.817), 24 h-1st SBP(88.7%/96.0%, κ-statistic = 0.833) and 24 h-2nd SBP (95.0%/88.1%, κ-statistic = 0.837). Similar observations were made for DBP. In ROC-analyses, all studied BP metrics showed excellent performance with high Area-Under-the- Curve values (20 h-1st: 0.983/0.992; 24 h-1st: 0.984/0.987 and 24 h-2nd: 0.982/0.989 for SBP/DBP respectively). Fixed 24 h ABPM recordings during either the first or the second day of interdialytic interval have high accuracy and strong agreement with 44 h BP in hemodialysis patients. Thus, ABPM recordings of either the first or the second interdialytic day could be used for hypertension diagnosis and management in these subjects.
Keywords: Ambulatory blood pressure monitoring; Hemodialysis; Hypertension; Interdialytic.
© 2024. The Author(s), under exclusive licence to The Japanese Society of Hypertension.
Similar articles
-
Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension.Int Urol Nephrol. 2023 Mar;55(3):729-740. doi: 10.1007/s11255-022-03369-0. Epub 2022 Sep 24. Int Urol Nephrol. 2023. PMID: 36153412 Free PMC article.
-
Accuracy of Peridialytic, Intradialytic, and Scheduled Interdialytic Recordings in Detecting Elevated Ambulatory Blood Pressure in Hemodialysis Patients.Am J Kidney Dis. 2021 Nov;78(5):630-639.e1. doi: 10.1053/j.ajkd.2021.01.022. Epub 2021 Apr 20. Am J Kidney Dis. 2021. PMID: 33857534
-
Association of peridialytic, intradialytic, scheduled interdialytic and ambulatory BP recordings with cardiovascular events in hemodialysis patients.J Nephrol. 2022 Apr;35(3):943-954. doi: 10.1007/s40620-021-01205-9. Epub 2022 Jan 6. J Nephrol. 2022. PMID: 34988941
-
Ambulatory blood pressure monitoring in pediatric end-stage renal disease: chronic dialysis and transplantation.Blood Press Monit. 1999 Jun-Aug;4(3-4):171-4. Blood Press Monit. 1999. PMID: 10490870 Review.
-
Short-term reproducibility of ambulatory blood pressure measurements: a systematic review and meta-analysis of 35 observational studies.J Hypertens. 2020 Nov;38(11):2095-2109. doi: 10.1097/HJH.0000000000002522. J Hypertens. 2020. PMID: 32555001 Free PMC article.
Cited by
-
Beta-blockers in patients with intradialytic hypertension: are they potent anti-hypertensives?Int Urol Nephrol. 2024 Oct;56(10):3409-3410. doi: 10.1007/s11255-024-04073-x. Epub 2024 May 7. Int Urol Nephrol. 2024. PMID: 38713417 No abstract available.
References
-
- Sarafidis PA, Persu A, Agarwal R, Burnier M, de Leeuw P, Ferro C, et al. Hypertension in dialysis patients: a consensus document by the European Renal and Cardiovascular Medicine (EURECA-m) working group of the European Renal Association - European Dialysis and Transplant Association (ERA-EDTA) and the Hypertension and the Kidney working group of the European Society of Hypertension (ESH). J Hypertens. 2017;35:657–76. - DOI - PubMed
-
- Sarafidis PA, Mallamaci F, Loutradis C, Ekart R, Torino C, Karpetas A, et al. Prevalence and control of hypertension by 48-h ambulatory blood pressure monitoring in haemodialysis patients: a study by the European Cardiovascular and Renal Medicine (EURECA-m) working group of the ERA-EDTA. Nephrol Dial Transpl. 2018;33:1872. - DOI
-
- K/DOQI Workgroup. K/DOQI clinical practice guidelines for cardiovascular disease in dialysis patients. Am J Kidney Dis. 2005;45:S1–153.
-
- Zoccali C, Tripepi R, Torino C, Tripepi G, Mallamaci F. Moderator’s view: ambulatory blood pressure monitoring and home blood pressure for the prognosis, diagnosis and treatment of hypertension in dialysis patients. Nephrol Dial Transpl. 2015;30:1443–8. - DOI
MeSH terms
LinkOut - more resources
Full Text Sources
Medical