Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2024 Jan 31;19(1):e0292800.
doi: 10.1371/journal.pone.0292800. eCollection 2024.

Quantitative somatosensory assessments in patients with persistent pain following groin hernia repair: A systematic review with a meta-analytical approach

Affiliations
Meta-Analysis

Quantitative somatosensory assessments in patients with persistent pain following groin hernia repair: A systematic review with a meta-analytical approach

Akhmedkhan Dubayev et al. PLoS One. .

Abstract

Objectives: Quantitative sensory testing (QST) provides an assessment of cutaneous and deep tissue sensitivity and pain perception under normal and pathological settings. Approximately 2-4% of individuals undergoing groin hernia repair (GHR) develop severe persistent postsurgical pain (PPSP). The aims of this systematic review of PPSP-patients were (1) to retrieve and methodologically characterize the available QST literature and (2) to explore the role of QST in understanding mechanisms underlying PPSP following GHR.

Methods: A systematic literature search was conducted from JAN-1992 to SEP-2022 in PubMed, EMBASE, and Google Scholar. For inclusion, studies had to report at least one QST-modality in patients with PPSP. Risk of bias assessment of the studies was conducted utilizing the Newcastle Ottawa Scale and Cochrane's Risk of Bias assessment tool 2.0. The review provided both a qualitative and quantitative analysis of the results. A random effects model was used for meta-analysis.

Results: Twenty-five studies were included (5 randomized controlled trials, 20 non-randomized controlled trials). Overall, risk of bias was low. Compared with the contralateral side or controls, there were significant alterations in somatosensory function of the surgical site in PPSP-patients. Following thresholds were significantly increased: mechanical detection thresholds for punctate stimuli (mean difference (95% CI) 3.3 (1.6, 6.9) mN (P = 0.002)), warmth detection thresholds (3.2 (1.6, 4.7) °C (P = 0.0001)), cool detection thresholds (-3.2 (-4.9, -1.6) °C (P = 0.0001)), and heat pain thresholds (1.9 (1.1, 2.7) °C (P = 0.00001)). However, the pressure pain thresholds were significantly decreased (-76 (-123, -30) kPa (P = 0.001)).

Conclusion: Our review demonstrates a plethora of methods used regarding outcome assessments, data processing, and data interpretation. From a pathophysiological perspective, the most consistent findings were postsurgical cutaneous deafferentation and development of a pain generator in deeper connective tissues.

Trial registration: CRD42022331750.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Fig 1
Fig 1. PRISMA 2020 flow diagram for new systematic reviews which included searches of databases, registers and other sources.
*Consider, if feasible to do so, reporting the number of records identified from each database or register searched (rather than the total number across all databases/registers). **If automation tools were used, indicate how many records were excluded by a human and how many were excluded by automation tools. From: Page MJ, McKenzie JE. Bossuyt PM, Boutron l, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021; 372:n71. doi: 10.1136/bmj.n71. For more information, visit: http://www.prisma-statement.org/.
Fig 2
Fig 2. Forest plots illustrating the results of various QST-modalities in the surgical site of GHR patients with PPSP compared to a reference site (contralateral side or healthy subjects).
The panels (A-G) illustrate assessments of mechanical detection thresholds (A), mechanical pain thresholds (B), warmth detection thresholds (C), heat pain thresholds (D), cool detection thresholds (E), cold pain thresholds (F), and blunt pressure pain thresholds (G) [23].
Fig 3
Fig 3. Summary of the risk of bias assessments of included RCTs using RoB 2.0 [22].

References

    1. Werner MU, Jensen EK. The Harald Breivik lecture 2022. Pathophysiology in persistent severe pain after groin hernia repair. Scand J Pain. 2022;22(4):686–9. doi: 10.1515/sjpain-2022-0103 - DOI - PubMed
    1. Aiolfi A, Cavalli M, Ferraro SD, Manfredini L, Bonitta G, Bruni PG, et al.. Treatment of Inguinal Hernia: Systematic Review and Updated Network Meta-analysis of Randomized Controlled Trials. Ann Surg. 2021;274(6):954–61. doi: 10.1097/SLA.0000000000004735 - DOI - PubMed
    1. Fadaee N, Mazer L, Sharma R, Capati I, Balzer B, Towfigh S. Clinical Value of Hernia Mesh Pathology Evaluation. J Am Coll Surg. 2019;228(5):776–81. doi: 10.1016/j.jamcollsurg.2019.02.038 - DOI - PubMed
    1. Bendavid R, Lou W, Grischkan D, Koch A, Petersen K, Morrison J, et al.. A mechanism of mesh-related post-herniorrhaphy neuralgia. Hernia. 2016;20(3):357–65. doi: 10.1007/s10029-015-1436-8 - DOI - PubMed
    1. Iakovlev V, Koch A, Petersen K, Morrison J, Grischkan D, Oprea V, et al.. A Pathology of Mesh and Time: Dysejaculation, Sexual Pain, and Orchialgia Resulting From Polypropylene Mesh Erosion Into the Spermatic Cord. Ann Surg. 2018;267(3):569–75. doi: 10.1097/SLA.0000000000002134 - DOI - PubMed