In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope
- PMID: 38305377
- DOI: 10.1097/ICL.0000000000001074
In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope
Abstract
Purpose: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated.
Methods: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior.
Results: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area ( P <0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses ( R >0.5, P <0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens ( P <0.05).
Conclusions: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.
Copyright © 2024 Contact Lens Association of Ophthalmologists.
Conflict of interest statement
The authors have no funding or conflicts of interest to disclose.
References
-
- Keir N, Jones L. Wettability and silicone hydrogel lenses: A review. Eye Contact Lens 2013;39:100–108.
-
- Montes-Mico R, Caliz A, Alio JL. Wavefront analysis of higher order aberrations in dry eye patients. J Refract Surg 2004;20:243–247.
-
- Montes-Mico R, Alio JL, Charman WN. Dynamic changes in the tear film in dry eyes. Invest Ophthalmol Vis Sci 2005;46:1615–1619.
-
- Jones L, Brennan NA, González-Méijome J, et al. The TFOS international workshop on contact lens discomfort: Report of the contact lens materials, design, and care subcommittee. Invest Ophthalmol Vis Sci 2013;54:Tfos37–Tfos70.
-
- Stapleton F, Tan J. Impact of contact lens material, design, and fitting on discomfort. Eye Contact Lens 2017;43:32–39.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources