In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope

Affiliations

In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope

Carlos Carpena-Torres et al. Eye Contact Lens. .

Abstract

Purpose: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated.

Methods: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior.

Results: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area ( P <0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses ( R >0.5, P <0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens ( P <0.05).

Conclusions: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.

PubMed Disclaimer

Conflict of interest statement

The authors have no funding or conflicts of interest to disclose.

References

    1. Keir N, Jones L. Wettability and silicone hydrogel lenses: A review. Eye Contact Lens 2013;39:100–108.
    1. Montes-Mico R, Caliz A, Alio JL. Wavefront analysis of higher order aberrations in dry eye patients. J Refract Surg 2004;20:243–247.
    1. Montes-Mico R, Alio JL, Charman WN. Dynamic changes in the tear film in dry eyes. Invest Ophthalmol Vis Sci 2005;46:1615–1619.
    1. Jones L, Brennan NA, González-Méijome J, et al. The TFOS international workshop on contact lens discomfort: Report of the contact lens materials, design, and care subcommittee. Invest Ophthalmol Vis Sci 2013;54:Tfos37–Tfos70.
    1. Stapleton F, Tan J. Impact of contact lens material, design, and fitting on discomfort. Eye Contact Lens 2017;43:32–39.

LinkOut - more resources