Abstract
The inherent biological hazards associated with ionizing radiation necessitate the implementation of effective shielding measures, particularly in medical applications. Interventional radiology, in particular, poses a unique challenge as it often exposes medical personnel to prolonged periods of high x-ray doses. Historically, lead and lead-based compounds have been the primary materials employed for shielding against photons. However, the drawbacks of lead, including its substantial weight causing personnel's inflexibility and its toxicity, have raised concerns regarding its long-term impact on both human health and the environment. Barium tantalate has emerged as a promising alternative, due to its unique attenuation properties against low-energy x-rays, specifically targeting the weak absorption area of lead. In the present study, we employ the Geant4 Monte Carlo simulation tool to investigate various formulations of barium tantalate doped with rare earth elements. The aim is to identify the optimal composition for shielding x-rays in the context of interventional radiology. To achieve this, we employ a reference x-ray spectrum typical of interventional radiology procedures, with energies extending up to 90 keV, within a carefully designed simulation setup. Our primary performance indicator is the reduction in air kerma transmission. Furthermore, we assess the absorbed doses to critical organs at risk within a standard human body phantom protected by the shield. Our results demonstrate that specific concentrations of the examined rare earth impurities can enhance the shielding performance of barium tantalate. To mitigate x-ray exposure in interventional radiology, our analysis reveals that the most effective shielding performance is achieved when using barium tantalate compositions containing 15% Erbium or 10% Samarium by weight. These findings suggest the possibility of developing lead-free shielding solutions or apron for interventional radiology personnel, offering a remarkable reduction in weight (exceeding 30%) while maintaining shielding performance at levels comparable to traditional lead-based materials.
Keywords: Geant4; Monte Carlo; barium tantalate; interventional radiology; radiation shielding.
Creative Commons Attribution license.
Similar articles
-
Efficiency in radiation protection of a novel exoskeleton-based interventional radiology apron and correlation with conventional aprons.Eur J Radiol. 2025 Mar;184:111946. doi: 10.1016/j.ejrad.2025.111946. Epub 2025 Jan 31. Eur J Radiol. 2025. PMID: 39946813
-
Intercomparison of active personal dosemeters in interventional radiology.Radiat Prot Dosimetry. 2008;129(1-3):340-5. doi: 10.1093/rpd/ncn083. Epub 2008 May 24. Radiat Prot Dosimetry. 2008. PMID: 18503062
-
Shielding performance of multi-metal nanoparticle composites for diagnostic radiology: an MCNPX and Geant4 study.Radiol Phys Technol. 2023 Mar;16(1):57-68. doi: 10.1007/s12194-022-00690-2. Epub 2022 Dec 23. Radiol Phys Technol. 2023. PMID: 36562940
-
[New-old methods of reducing and monitoring x-ray exposure in the interventional radiology environment].Med Pr. 2021 Feb 3;72(1):49-59. doi: 10.13075/mp.5893.01022. Epub 2020 Oct 27. Med Pr. 2021. PMID: 33162557 Review. Polish.
-
Development of Lead-Free Materials for Radiation Shielding in Medical Settings: A Review.J Biomed Phys Eng. 2024 Jun 1;14(3):229-244. doi: 10.31661/jbpe.v0i0.2404-1742. eCollection 2024 Jun. J Biomed Phys Eng. 2024. PMID: 39027711 Free PMC article. Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources