Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2024 Apr 10;78(4):937-948.
doi: 10.1093/cid/ciae035.

Compared Performance of the 2023 Duke-International Society for Cardiovascular Infectious Diseases, 2000 Modified Duke, and 2015 European Society of Cardiology Criteria for the Diagnosis of Infective Endocarditis in a French Multicenter Prospective Cohort

Collaborators, Affiliations
Multicenter Study

Compared Performance of the 2023 Duke-International Society for Cardiovascular Infectious Diseases, 2000 Modified Duke, and 2015 European Society of Cardiology Criteria for the Diagnosis of Infective Endocarditis in a French Multicenter Prospective Cohort

Francois Goehringer et al. Clin Infect Dis. .

Abstract

Background: The 2023 Duke-International Society for Cardiovascular Diseases (ISCVID) criteria for infective endocarditis (IE) were proposed as an updated diagnostic classification of IE. Using an open prospective multicenter cohort of patients treated for IE, we compared the performance of these new criteria to that of the 2000 Modified Duke and 2015 European Society of Cardiology (ESC) criteria.

Methods: Cases of patients treated for IE between January 2017 and October 2022 were adjudicated as certain IE or not. Each case was also categorized as either definite or possible/rejected within each classification. Sensitivity, specificity, and accuracy were estimated with 95% confidence intervals.

Results: Of the 1194 patients analyzed (mean age, 66.1 years; 71.2% males), 414 (34.7%) had a prosthetic valve and 284 (23.8%) had a cardiac implanted electronic device (CIED); 946 (79.2%) were adjudicated as certain IE; 978 (81.9%), 997 (83.5%), and 1057 (88.5%) were classified as definite IE in the 2000 modified Duke, 2015 ESC, and 2023 Duke-ISCVID criteria, respectively. The sensitivity of each set of criteria was 93.2% (95% confidence interval [CI], 91.6-94.8), 95.0% (95% CI, 93.7-96.4), and 97.6% (95% CI, 96.6-98.6), respectively (P < .001 for all 2-by-2 comparisons). Corresponding specificity rates were 61.3% (95% CI, 55.2-67.4), 60.5% (95% CI, 54.4-66.6), and 46.0% (95% CI, 39.8-52.2), respectively. In patients without CIED, sensitivity rates were 94.8% (95% CI, 93.2-96.4), 96.5% (95% CI, 95.1-97.8), and 97.7% (95% CI, 96.6-98.8); specificity rates were 59.0% (95% CI, 51.6-66.3), 56.6% (95% CI, 49.3-64.0), and 53.8% (95% CI, 46.3-61.2), respectively.

Conclusions: Overall, the 2023 Duke-ISCVID criteria had a significantly higher sensitivity but a significantly lower specificity compared with older criteria. This decreased specificity was mainly attributable to patients with CIED.

Keywords: 2023 Duke–ISCVID criteria; accuracy; infective endocarditis; sensitivity; specificity.

PubMed Disclaimer

Conflict of interest statement

Potential conflicts of interest. The authors: No reported conflicts of interest. All authors have submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest.

Comment in

References

Publication types