Assessing Physicochemical Stability of Monoclonal Antibodies in a Simulated Subcutaneous Environment
- PMID: 38341129
- DOI: 10.1016/j.xphs.2024.02.004
Assessing Physicochemical Stability of Monoclonal Antibodies in a Simulated Subcutaneous Environment
Abstract
Monoclonal antibodies (mAbs) are being increasingly administered by the subcutaneous (SC) route compared to the traditional intravenous route. Despite the growing popularity of the subcutaneous route, our current knowledge regarding the intricate mechanistic changes happening in the formulation after injection in the subcutaneous space, as well as the in vivo stability of administered mAbs, remains quite limited. Changes in the protein environment as it transitions from a stabilized, formulated drug product in an appropriate container closure to the SC tissue environment can drastically impact the structural stability and integrity of the injected protein. Interactions of the protein with components of the extracellular matrix can lead to changes in its structure, potentially impacting both safety and efficacy. Investigating protein stability in the SC space can enable early assessment of risk and performance of subcutaneously administered proteins influencing clinical decisions and formulation development strategies. The Subcutaneous Injection Site Simulator (SCISSOR) is a novel in vitro system that mimics the subcutaneous injection site and models the events that a protein goes through as it transitions from a stabilized formulation environment to the dynamic physiological space. In this paper, we utilize the SCISSOR to probe for biophysical and chemical changes in seven mAbs post SC injection using a variety of analytical techniques. After 24 h, all mAbs demonstrated a relative decrease in conformational stability, an increase in fragmentation, and elevated acidic species. Higher order structure analysis revealed a deviation in the secondary structure from the standard and an increase in the number of unordered species. Our findings suggest an overall reduced stability of mAbs after subcutaneous administration. This reduced stability could have a potential impact on safety and efficacy. In vitro systems such as the SCISSOR combined with downstream analyses have potential to provide valuable information for assessing the suitability of lead molecules and aid in formulation design optimized for administration in the intended body compartment, thus improving chances of clinical success.
Keywords: Biophysical; In vitro models; Monoclonal antibodies; Subcutaneous administration.
Copyright © 2024 American Pharmacists Association. Published by Elsevier Inc. All rights reserved.
Conflict of interest statement
Declaration of competing interest No conflict of interest to be reported.
Comment in
-
A Thermodynamic Approach to Characterizing Monoclonal Antibody Stability in a Subcutaneous Environment.J Pharm Sci. 2024 Aug;113(8):2656-2657. doi: 10.1016/j.xphs.2024.03.020. Epub 2024 Mar 28. J Pharm Sci. 2024. PMID: 38554929 No abstract available.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
