Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites
- PMID: 38349819
- DOI: 10.2341/23-025-L
Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites
Abstract
Objectives: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC).
Methods: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulk-fill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photo-cured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm2, resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm2. Post-gel shrinkage (Shr) was calculated using strain-gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm2) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split-plot repeated measurement tests followed by the Tukey test (a = 0.05).
Results: Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R2=0.808-0.922; R2=0.648-0.914, p<0.001), KH (R2=0.707-0.952; R2=0.738-0.919; p<0.001), and E (R2=0.501-0.925; R2=0.823-0.919; p<0.001) values for the flowable and high-viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk-fill RBCs. All bulk-fill RBCs had a radiopacity level greater than the 4-mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity.
Conclusion: The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm2 to 48 J/cm2 produced better results than delivering 400 mW/cm2 for 40 s (16 J/cm2), and 800 mW/cm2 for 20 seconds (16 J/cm2) or 1200 mW/cm2 for 10 seconds (12 J/cm2). All the bulk-fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.
©Operative Dentistry, 2024.
Similar articles
-
Effect of Using Manufacturer-recommended Exposure Times to Photo-activate Bulk-fill and Conventional Resin-based Composites.Oper Dent. 2023 May 1;48(3):304-316. doi: 10.2341/22-021-L. Oper Dent. 2023. PMID: 36917633
-
Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites.Dent Mater. 2023 Mar;39(3):275-292. doi: 10.1016/j.dental.2023.01.007. Epub 2023 Mar 1. Dent Mater. 2023. PMID: 36868892
-
Comparison of Polymerization Shrinkage, Physical Properties, and Marginal Adaptation of Flowable and Restorative Bulk Fill Resin-Based Composites.Oper Dent. 2017 Jul/Aug;42(4):375-386. doi: 10.2341/16-254-L. Epub 2017 Apr 12. Oper Dent. 2017. PMID: 28402737
-
Investigations on a methacrylate-based flowable composite based on the SDR™ technology.Dent Mater. 2011 Apr;27(4):348-55. doi: 10.1016/j.dental.2010.11.014. Epub 2010 Dec 30. Dent Mater. 2011. PMID: 21194743
-
Effect of ultra-fast high-intensity light-curing on the properties of a new bulk-fill restorative resin composite system: A Scoping Review.J Clin Exp Dent. 2024 Jul 1;16(7):e898-e911. doi: 10.4317/jced.61661. eCollection 2024 Jul. J Clin Exp Dent. 2024. PMID: 39219826 Free PMC article.
Cited by
-
Effect of Three Heating Guns on the Temperature of Two Bulk-Fill Resin-Based Composites.J Esthet Restor Dent. 2025 Jul;37(7):1802-1813. doi: 10.1111/jerd.13457. Epub 2025 Mar 17. J Esthet Restor Dent. 2025. PMID: 40091573 Free PMC article.
-
Effect of matrix system on the quality of proximal contact in posterior bulk-fill resin composite restorations- an in vitro study.Clin Oral Investig. 2025 Jun 10;29(7):337. doi: 10.1007/s00784-025-06402-5. Clin Oral Investig. 2025. PMID: 40490628
-
Influence of Layer Thickness and Shade on the Transmission of Light through Contemporary Resin Composites.Materials (Basel). 2024 Mar 28;17(7):1554. doi: 10.3390/ma17071554. Materials (Basel). 2024. PMID: 38612069 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous