Randomized Controlled Trial
. 2024 Feb 14;24(1):136.
doi: 10.1186/s12884-024-06322-4.

Large-scale analysis of interobserver agreement and reliability in cardiotocography interpretation during labor using an online tool

Affiliations
Randomized Controlled Trial

Large-scale analysis of interobserver agreement and reliability in cardiotocography interpretation during labor using an online tool

Imane Ben M'Barek et al. BMC Pregnancy Childbirth. .

Abstract

Background: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor.

Material and methods: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively.

Results: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63).

Conclusions: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.

Keywords: Cardiotocography; Fetal heart rate; Fetal hypoxia; Interobserver agreement; Intrapartum; Labor.

PubMed Disclaimer

Conflict of interest statement

GJ and BB are shareholders of Genos Care, a company building medical software.

Figures

Fig. 1
Fig. 1
Graphical representation of the participants’ performance. TPR true positive rate, FPR false positive rate
Fig. 2
Fig. 2
Mean success rate per pH range

Similar articles

Cited by

References

    1. Wang B, Zeng H, Liu J, Sun M. Effects of Prenatal Hypoxia on Nervous System Development and Related Diseases. Front Neurosci. 2021;15. Cited 2023 Feb 10. Available from: https://www.frontiersin.org/articles/10.3389/fnins.2021.755554. - DOI - PMC - PubMed
    1. FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography - Ayres‐de‐Campos - 2015 - International Journal of Gynecology & Obstetrics - Wiley Online Library. Cited 2021 Jun 30. Available from: https://obgyn.onlinelibrary.wiley.com/doi/10.1016/j.ijgo.2015.06.020. - DOI - PubMed
    1. Recommendations | Fetal monitoring in labour | Guidance | NICE. NICE; 2022. Cited 2023 Apr 12. Available from: https://www.nice.org.uk/guidance/ng229/chapter/Recommendations.
    1. Carbonne B, Dreyfus M, Schaal JP, Bretelle F, Dupuis O, Foulhy C, et al. Classification CNGOF du rythme cardiaque fœtal : obstétriciens et sages-femmes au tableau ! J de Gynécologie Obstétrique et Biologie de la Reprod. 2013;42(6):509–10. doi: 10.1016/j.jgyn.2013.07.003. - DOI - PubMed
    1. Svenska riktlinjer för bedömning av antepartalt CTG. Cited 2023 May 3. Available from: https://ctgutbildning.se/index.php/om-utbildningen/riktlinjer-2.

Publication types