Improving image quality using the pause function combination to PROPELLER sequence in brain MRI: a phantom study
- PMID: 38367143
- DOI: 10.1007/s12194-024-00784-z
Improving image quality using the pause function combination to PROPELLER sequence in brain MRI: a phantom study
Abstract
While some MRI systems offer a "pause" function, combining it with the PROPELLER method for image quality improvement remains underexplored. This study investigated whether repositioning the head after pausing during PROPELLER imaging enhances image quality. All brain phantom images in this study were obtained using a 3.0 T MRI and acquired using the fast spin-echo T2WI-based PROPELLER with motion correction. By combining the angle of rotational motion of the head phantom and the number of repositioning after a pause, two studies including seven trials were performed. Increasing the rotation angle decreased the image quality; however, pausing the image and repositioning the head phantom to the original angle improved the image quality. A similar result was obtained by repositioning the angle closer to its original angle. Experiments with multiple head movements showed that pausing the scan and repositioning the phantom with each movement improved image quality.
Keywords: Brain; Magnetic resonance imaging; PROPELLER; Pause; Phantom; Radial scan.
© 2024. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.
Similar articles
-
A brain phantom for motion-corrected PROPELLER showing image contrast and construction similar to those of in vivo MRI.Magn Reson Imaging. 2017 Feb;36:32-39. doi: 10.1016/j.mri.2016.10.003. Epub 2016 Oct 11. Magn Reson Imaging. 2017. PMID: 27742431
-
[Evaluation of the Latest Motion Correction Techniques in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) Imaging across Different Vendors].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2024 Nov 20;80(11):1155-1164. doi: 10.6009/jjrt.2024-1520. Epub 2024 Oct 19. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2024. PMID: 39428468 Japanese.
-
Simultaneous multi-slice combined with PROPELLER.Magn Reson Med. 2018 Aug;80(2):496-506. doi: 10.1002/mrm.27041. Epub 2017 Dec 19. Magn Reson Med. 2018. PMID: 29266393
-
Phantoms for Quantitative Body MRI: a review and discussion of the phantom value.MAGMA. 2024 Aug;37(4):535-549. doi: 10.1007/s10334-024-01181-8. Epub 2024 Jun 19. MAGMA. 2024. PMID: 38896407 Free PMC article. Review.
-
Scoping review of magnetic resonance motion imaging phantoms.MAGMA. 2024 Oct;37(5):791-805. doi: 10.1007/s10334-024-01164-9. Epub 2024 May 13. MAGMA. 2024. PMID: 38739218
Cited by
-
Self-supervised learning for MRI reconstruction: a review and new perspective.MAGMA. 2025 Jun 26. doi: 10.1007/s10334-025-01274-y. Online ahead of print. MAGMA. 2025. PMID: 40569542 Review.
References
-
- Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Okada T, et al. Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique–evaluation of SPIO-enhanced T2-weighted MR images. Radiology. 2009;251:388–97. - DOI - PubMed
-
- Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging. 2008;28:957–62. - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Medical