. 2024;53(5):405-417.
doi: 10.1159/000536181. Epub 2024 Feb 21.

The Use of Anemia Control Model Is Associated with Improved Hemoglobin Target Achievement, Lower Rates of Inappropriate Erythropoietin Stimulating Agents, and Severe Anemia among Dialysis Patients

Affiliations

The Use of Anemia Control Model Is Associated with Improved Hemoglobin Target Achievement, Lower Rates of Inappropriate Erythropoietin Stimulating Agents, and Severe Anemia among Dialysis Patients

Mario Garbelli et al. Blood Purif. 2024.

Abstract

Introduction: The Anemia Control Model (ACM) is a certified medical device suggesting the optimal ESA and iron dosage for patients on hemodialysis. We sought to assess the effectiveness and safety of ACM in a large cohort of hemodialysis patients.

Methods: This is a retrospective study of dialysis patients treated in NephroCare centers between June 1, 2013 and December 31, 2019. We compared patients treated according to ACM suggestions and patients treated in clinics where ACM was not activated. We stratified patients belonging to the reference group by historical target achievement rates in their referral centers (tier 1: <70%; tier 2: 70-80%; tier 3: >80%). Groups were matched by propensity score.

Results: After matching, we obtained four groups with 85,512 patient-months each. ACM had 18% higher target achievement rate, 63% smaller inappropriate ESA administration rate, and 59% smaller severe anemia risk compared to Tier 1 centers (all p < 0.01). The corresponding risk ratios for ACM compared to Tier 2 centers were 1.08 (95% CI: 1.08-1.09), 0.49 (95% CI: 0.47-0.51), and 0.64 (95% CI: 0.61-0.68); for ACM compared to Tier 3 centers, 1.01 (95% CI: 1.01-1.02), 0.66 (95% CI: 0.63-0.69), and 0.94 (95% CI: 0.88-1.00), respectively. ACM was associated with statistically significant reductions in ESA dose administration.

Conclusion: ACM was associated with increased hemoglobin target achievement rate, decreased inappropriate ESA usage and a decreased incidence of severe anemia among patients treated according to ACM suggestion.

Keywords: Anemia management; Artificial intelligence; End stage kidney disease; Erythropoietin stimulating agents; Hemoglobin; Medical device; Secondary anemia.

PubMed Disclaimer

Conflict of interest statement

Mario Garbelli, Francesco Bellocchio, Maria Eva Baro Salvador, Milena Chermisi, Abraham Rincon Bello, Isabel Berdud Godoy, Sofia Ortego Perez, Kateryna Shkolenko, Alicia Sobrino Perez, Diana Samaniego Toro, Christian Apel, Jovana Petrovic, Stefano Stuard, Carlo Barbieri, Flavio Mari, and Luca Neri are employees of Fresenius Medical Care. Carlo Barbieri and Stefano Stuard have share options/ownership in Fresenius Medical Care. The remaining author declares no commercial or financial conflict of interest.