Abstract
Background and aims: With the global obesity pandemic, clinical scenarios requiring urgent ERCP in patients with gastric bypass surgery are on the rise, and single-session EUS-directed transgastric ERCP (SS-EDGE) can effectively address these technical challenges. The aim of this study was to evaluate and describe the safe and effective use of a through-the-scope endoscopic suturing system for anchoring the lumen-apposing metal stents (LAMSs) during SS-EDGE.
Methods: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. A through-the-scope endoscopic suturing system was used for anchoring the LAMSs during SS-EDGE.
Results: Clinical and technical success was achieved in all 6 patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum, or GI perforation was noted. At the 4-week follow-up, no stent migration was noted, and the through-the-scope suturing system remained anchored. LAMSs along with tacks were removed, and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain.
Conclusions: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients.
Copyright © 2024 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Conflict of interest statement
Disclosure The following authors disclosed financial relationships: D. Yang: Consultant for Olympus, Fujifilm, Apollo Endosurgery, Medtronic, 3D-Matrix, and MicroTech. M. K. Hasan: Consultant for Olympus America, Boston Scientific, and MicroTech Endoscopy. All other authors disclosed no financial relationships.