Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 May;47(5):2097-2105.
doi: 10.1016/j.asjsur.2024.02.094. Epub 2024 Feb 20.

A systematic review on sonoelastography for rotator-cuff post-repair assessment

Affiliations
Free article

A systematic review on sonoelastography for rotator-cuff post-repair assessment

Ting-Yu Lin et al. Asian J Surg. 2024 May.
Free article

Abstract

Surgical repair of rotator cuff tears is performed routinely; however, the risks of re-tears and the associated consequences are significant. Sonoelastography, an imaging modality that evaluates the mechanical properties of tissues, can examine the dynamic transitions in rotator cuff stiffness following retear and investigate the relationship between these changes and the occurrences of retears. This systematic review aimed to summarize the role of perioperative sonoelastography in repaired rotator cuffs. A comprehensive search of the PubMed, Embase, and Cochrane databases was conducted, covering studies published until June 19, 2023. The Newcastle-Ottawa scale was used for quality assessment. The key information extracted from each study included the injury/surgery type, follow-up duration, sonoelastography mode, and main sonoelastographic findings. Eleven eligible studies comprising 355 patients were included. All studies focused on supraspinatus muscles and tendons with previous arthroscopic repairs. During the postoperative 1st - 6th months, muscle stiffness increased in the supraspinatus and decreased in the ipsilateral deltoid. Failure to recover supraspinatus muscle elasticity might be indicative of potential tendon re-tear; however, it is imperative to first establish correlations with other imaging modalities. Conflicting findings have been observed regarding stiffening or softening of the supraspinatus tendon after surgical repair. The preoperative stiffness of the supraspinatus tendon did not correlate with postoperative tendon integrity or function.

Keywords: Arthroscopy; Shear wave; Shoulder; Supraspinatus; Tear; Tendon; Ultrasound.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no conflict of interest.

Similar articles

Publication types

MeSH terms

LinkOut - more resources