Laboratory and clinical evaluation of a rapid slide agglutination test for phosphatidylglycerol
- PMID: 3838619
- DOI: 10.1016/0002-9378(85)90381-3
Laboratory and clinical evaluation of a rapid slide agglutination test for phosphatidylglycerol
Abstract
Amniostat-FLM is a recently developed rapid slide agglutination test for amniotic fluid phosphatidylglycerol. We compared phosphatidylglycerol quantitated by two-dimensional thin-layer chromatography with phosphatidylglycerol determined by Amniostat-FLM in 180 amniotic fluid samples. If any level of phosphatidylglycerol by thin-layer chromatography, including a trace, was considered positive, then phosphatidylglycerol by thin-layer chromatography and Amniostat-FLM were concordant in 171 of 180 samples (95%). Both were positive in 123 and both negative in 48 samples. The nine amniotic fluid samples with discrepant results were as follows: Five negative Amniostat-FLM results were associated with trace phosphatidylglycerol by thin-layer chromatography (1% to 2% of total phospholipids), one negative Amniostat-FLM result was associated with 3% phosphatidylglycerol by thin-layer chromatography, and three positive Amniostat-FLM results were associated with negative phosphatidylglycerol by thin-layer chromatography results. There were 14 samples with trace phosphatidylglycerol by thin-layer chromatography; of these, there were nine positive and five negative Amniostat-FLM results. If greater than 2% phosphatidylglycerol by thin-layer chromatography was considered positive, concordance between the two tests was 93% (167 of 180). From these samples, 119 infants were delivered within 72 hours of amniocentesis. There were 100 positive Amniostat-FLM results and all were associated with the absence of respiratory distress syndrome; of the 19 negative Amniostat-FLM results, five were associated with infants who developed respiratory distress syndrome. The present study confirms that Amniostat-FLM is a simple, rapid, and accurate test for determining the presence of phosphatidylglycerol in amniotic fluid.
Similar articles
-
Amniostat-FLM: an initial clinical trial with both vaginal pool and amniocentesis samples.Am J Obstet Gynecol. 1986 Jan;154(1):65-8. doi: 10.1016/0002-9378(86)90394-7. Am J Obstet Gynecol. 1986. PMID: 3511707 Clinical Trial.
-
Evaluation of the Amniostat-FLM assay for assessment of fetal lung maturity.Clin Chem. 1984 Jul;30(7):1233-7. Clin Chem. 1984. PMID: 6733906
-
Amniostat FLM: a new technique for detection of phosphatidylglycerol in amniotic fluid.Am J Perinatol. 1985 Apr;2(2):88-92. doi: 10.1055/s-2007-999921. Am J Perinatol. 1985. PMID: 4096763
-
Strategic utilization of fetal lung maturity tests.Scand J Clin Lab Invest. 1996 Oct;56(6):525-32. doi: 10.3109/00365519609088808. Scand J Clin Lab Invest. 1996. PMID: 8903114 Review.
-
Determination of fetal maturity.Clin Perinatol. 1982 Jun;9(2):297-312. Clin Perinatol. 1982. PMID: 6749372 Review.
Cited by
-
Techniques to evaluate surfactant activity for a personalized therapy of RDS neonates.Biomed J. 2021 Dec;44(6):671-677. doi: 10.1016/j.bj.2021.11.001. Epub 2021 Nov 7. Biomed J. 2021. PMID: 34758409 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources