Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: a retrospective cohort study from a single academic institution
- PMID: 38388720
- DOI: 10.1007/s00330-024-10663-1
Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: a retrospective cohort study from a single academic institution
Abstract
Objectives: To evaluate diagnostic yield and accuracy of image-guided core needle biopsy (ICNB) of suspected malignant osseous lesions in a large cohort of adults, evaluate what factors influence these measures, and offer technical recommendations to optimize yield.
Methods: A retrospective analysis of 2321 ICNBs performed from 2010 to 2021 was completed. The diagnostic yield and accuracy of the biopsies as well as a series of patient, lesion-related, and technical factors were retrospectively analyzed. Multivariate statistical analysis was performed to evaluate what factors were associated with yield and accuracy. Different cutoff values of total core length and core number were then tested to determine threshold values in relation to increased diagnostic yield.
Results: Diagnostic yield was 98.2% (2279/2321) and accuracy was 97.6% (120/123). Increased total core length (odds ratio [OR] = 2.34, 95% confidence interval [CI] (1.41-3.90), p = 0.001), core number (OR = 1.51, 95% CI (1.06-2.16), p = 0.02) and presence of primary malignancy (OR = 2.81, 95% CI (1.40-5.62), p = 0.004) were associated with improved yield. Lesion location in an extremity (OR = 0.27, 95% CI (0.11-0.68), p = 0.006) and using fluoroscopic imaging guidance (OR = 0.33, 95% CI (0.12-0.90), p = 0.03) were associated with lower yield. Cutoff thresholds in relation to increased diagnostic yield were found to be 20 mm total core length (marginal OR = 4.16, 95% CI = (2.09-9.03), p < 0.001), and three total cores obtained (marginal OR = 2.78, 95% CI (1.34-6.54), p = 0.005). None of the analyzed factors influenced diagnostic accuracy.
Conclusions: ICNB has a high rate of diagnostic yield and accuracy. Several factors influence diagnostic yield; 20 mm core length and three total cores optimize yield.
Clinical relevance statement: Image-guided core needle biopsy of suspected malignant osseous lesions is a safe procedure with a very high rate of diagnostic yield and accuracy. Obtaining 20 mm total core length and three total cores optimizes diagnostic yield.
Key points: • In a retrospective cohort study, image-guided core needle biopsy of suspected osseous malignant lesions in adults was found to have very high rates of diagnostic yield and accuracy. • Increased total core length and core number of biopsies were each associated with increased diagnostic yield, and these relationships reached thresholds at 20 mm total core length and three total cores obtained. • The presence of a known primary malignancy was also associated with increased yield while using fluoroscopic imaging guidance and lesion location in an extremity were associated with decreased yield.
Keywords: Biopsy; Bone cancer; Interventional radiology; Metastases.
© 2024. The Author(s), under exclusive licence to European Society of Radiology.
Comment in
-
Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: pitfalls and factors affecting diagnostic yield.Eur Radiol. 2024 Sep;34(9):5758-5759. doi: 10.1007/s00330-024-10683-x. Epub 2024 Mar 14. Eur Radiol. 2024. PMID: 38483590 No abstract available.
Similar articles
-
Diagnostic efficacy and clinical impact of image-guided core needle biopsy of suspected vertebral osteomyelitis.Int J Infect Dis. 2024 Jul;144:107027. doi: 10.1016/j.ijid.2024.107027. Epub 2024 Apr 25. Int J Infect Dis. 2024. PMID: 38670483
-
Image guided core needle biopsy of musculoskeletal lesions: are nondiagnostic results clinically useful?Clin Orthop Relat Res. 2013 Nov;471(11):3601-9. doi: 10.1007/s11999-013-3170-9. Epub 2013 Jul 17. Clin Orthop Relat Res. 2013. PMID: 23861048 Free PMC article.
-
Image-guided core needle biopsy for Ewing sarcoma of bone: a 10-year single-institution review.Eur Radiol. 2020 Oct;30(10):5308-5314. doi: 10.1007/s00330-020-06926-2. Epub 2020 May 28. Eur Radiol. 2020. PMID: 32468104
-
Diagnostic Outcome of Image-Guided Percutaneous Core Needle Biopsy of Sclerotic Bone Lesions: A Meta-Analysis.AJR Am J Roentgenol. 2019 Mar;212(3):625-631. doi: 10.2214/AJR.18.20243. Epub 2018 Dec 27. AJR Am J Roentgenol. 2019. PMID: 30589380
-
Diagnostic outcome and safety of CT-guided core needle biopsy for mediastinal masses: a systematic review and meta-analysis.Eur Radiol. 2020 Jan;30(1):588-599. doi: 10.1007/s00330-019-06377-4. Epub 2019 Aug 15. Eur Radiol. 2020. PMID: 31418086
Cited by
-
Diagnostic efficacy of image-guided core needle biopsy of suspected malignant osseous lesions: pitfalls and factors affecting diagnostic yield.Eur Radiol. 2024 Sep;34(9):5758-5759. doi: 10.1007/s00330-024-10683-x. Epub 2024 Mar 14. Eur Radiol. 2024. PMID: 38483590 No abstract available.
References
-
- Veltri A, Bargellini I, Giorgi L, Almeida P, Akhan O (2017) CIRSE guidelines on percutaneous needle biopsy (PNB). Cardiovasc Inter Radiol 40(10):1501–1513 - DOI
MeSH terms
LinkOut - more resources
Full Text Sources
Medical