Dual-Mode Graphene Field-Effect Transistor Biosensor with Isothermal Nucleic Acid Amplification
- PMID: 38392010
- PMCID: PMC10886465
- DOI: 10.3390/bios14020091
Dual-Mode Graphene Field-Effect Transistor Biosensor with Isothermal Nucleic Acid Amplification
Abstract
Despite a substantial increase in testing facilities during the pandemic, access remains a major obstacle, particularly in low-resource and remote areas. This constraint emphasizes the need for high-throughput potential point-of-care diagnostic tools in environments with limited resources. Loop-mediated isothermal amplification (LAMP) is a promising technique, but improvements in sensitivity are needed for accurate detection, especially in scenarios where the virus is present in low quantities. To achieve this objective, we present a highly sensitive detection approach of a dual-mode graphene-based field-effect transistor (G-FET) biosensor with LAMP. The G-FET biosensor, which has a transparent graphene microelectrode array on a glass substrate, detects LAMP products in less than 30 min using both observable color changes and Dirac point voltage measurements, even in samples with low viral concentrations. This dual-mode G-FET biosensor emerges as a potential alternative to conventional RT-PCR for severe acute respiratory syndrome-associated coronavirus (SARS-CoV)-2 detection or point-of-care testing, particularly in resource-constrained scenarios such as developing countries. Moreover, its capacity for colorimetric detection with the naked eye enhances its applicability in diverse settings.
Keywords: SARS-CoV-2; colorimetric detection; graphene field-effect transistor; loop-mediated isothermal amplification; multi-array.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures




Similar articles
-
Detection of SARS-CoV-2 Virus Amplification Using a Crumpled Graphene Field-Effect Transistor Biosensor.ACS Sens. 2021 Dec 24;6(12):4461-4470. doi: 10.1021/acssensors.1c01937. Epub 2021 Dec 8. ACS Sens. 2021. PMID: 34878775
-
Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor.Front Cell Infect Microbiol. 2021 Jul 14;11:581239. doi: 10.3389/fcimb.2021.581239. eCollection 2021. Front Cell Infect Microbiol. 2021. PMID: 34336708 Free PMC article.
-
Sequence-specific and multiplex detection of COVID-19 virus (SARS-CoV-2) using proofreading enzyme-mediated probe cleavage coupled with isothermal amplification.Biosens Bioelectron. 2021 Apr 15;178:113041. doi: 10.1016/j.bios.2021.113041. Epub 2021 Jan 28. Biosens Bioelectron. 2021. PMID: 33545551 Free PMC article.
-
Loop-mediated isothermal amplification (LAMP): An effective molecular point-of-care technique for the rapid diagnosis of coronavirus SARS-CoV-2.Rev Med Virol. 2021 Nov;31(6):e2215. doi: 10.1002/rmv.2215. Epub 2021 Jan 21. Rev Med Virol. 2021. PMID: 33476080 Free PMC article. Review.
-
Isothermal amplification-assisted diagnostics for COVID-19.Biosens Bioelectron. 2022 Jun 1;205:114101. doi: 10.1016/j.bios.2022.114101. Epub 2022 Feb 17. Biosens Bioelectron. 2022. PMID: 35202984 Free PMC article. Review.
Cited by
-
Future perspectives of GMO detection in agriculture: strategies for electrochemical nucleic acid detection.Mikrochim Acta. 2025 Jun 26;192(7):457. doi: 10.1007/s00604-025-07267-x. Mikrochim Acta. 2025. PMID: 40571859 Free PMC article. Review.
References
-
- Acter T., Uddin N., Das J., Akhter A., Choudhury T.R., Kim S. Evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) as coronavirus disease 2019 (COVID-19) pandemic: A global health emergency. Sci. Total Environ. 2020;730:138996. doi: 10.1016/j.scitotenv.2020.138996. - DOI - PMC - PubMed
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous