Threshold for lens damage during Q-switched Nd:YAG laser iridectomy. A study of rhesus monkey eyes
- PMID: 3841196
- DOI: 10.1016/s0161-6420(85)33841-1
Threshold for lens damage during Q-switched Nd:YAG laser iridectomy. A study of rhesus monkey eyes
Abstract
Clinical and pathologic examinations were performed after 18 iridectomies had been created in six eyes of three rhesus monkeys using increasing Q-switched neodymium (Nd):YAG laser energy, pulses per burst, and number of bursts. Treatment parameters bracketed the threshold for lens damage during iridectomy. Iridectomy with one or two bursts of one or two Q-switched pulses at 5 to 6.2 mJ per pulse was achieved without lens damage. Slight increase of pulse energy or an increase to three pulses per burst (without pulse energy increase) caused local damage to the underlying lens. Marked increase of any of the treatment parameters caused slightly larger iridectomies and slightly larger, localized damage of the underlying lens. Synechiae developed between the monkey posterior iris surface at the iridectomy and the damaged area in 80% of the lens lesions. In monkeys, the small pulsed laser iridectomies created with pulses of energies up to 6.5 mJ became occluded during the healing process.
Similar articles
-
The effect of combined application of argon and Nd-YAG lasers on iridectomy in rabbits.Korean J Ophthalmol. 1989 Dec;3(2):47-54. doi: 10.3341/kjo.1989.3.2.47. Korean J Ophthalmol. 1989. PMID: 2635742
-
Endothelial damage thresholds for retrocorneal Q-switched neodymium:YAG laser pulses in monkeys.Ophthalmology. 1985 Oct;92(10):1382-6. doi: 10.1016/s0161-6420(85)33860-5. Ophthalmology. 1985. PMID: 3840876
-
Experimental iridotomy with the Q-switched neodymium-YAG laser.Arch Ophthalmol. 1984 Aug;102(8):1211-3. doi: 10.1001/archopht.1984.01040030981031. Arch Ophthalmol. 1984. PMID: 6547832
-
Analysis of diode, argon, and Nd: YAG peripheral iridectomy in cadaver eyes.Doc Ophthalmol. 1994;87(4):367-76. doi: 10.1007/BF01203345. Doc Ophthalmol. 1994. PMID: 7851220
-
Picosecond optical breakdown: tissue effects and reduction of collateral damage.Lasers Surg Med. 1989;9(3):193-204. doi: 10.1002/lsm.1900090302. Lasers Surg Med. 1989. PMID: 2659910 Review.
Cited by
-
Histopathological characteristics of neodymium-YAG laser iridotomy in the human eye.Br J Ophthalmol. 1987 Aug;71(8):623-8. doi: 10.1136/bjo.71.8.623. Br J Ophthalmol. 1987. PMID: 3651378 Free PMC article.
-
Neodymium: YAG laser iridotomies--short-term comparison with capsulotomies and long-term follow-up.Graefes Arch Clin Exp Ophthalmol. 1988;226(1):49-54. doi: 10.1007/BF02172718. Graefes Arch Clin Exp Ophthalmol. 1988. PMID: 3342976
-
Thresholds for beneficial and harmful effects during use of high-power, pulsed lasers to treat problems of the anterior segment of the eye.Trans Am Ophthalmol Soc. 1986;84:1004-32. Trans Am Ophthalmol Soc. 1986. PMID: 3590465 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources