A threshold of 100 or more colony-forming units on the anesthesia machine predicts bacterial pathogen detection: a retrospective laboratory-based analysis
- PMID: 38413516
- DOI: 10.1007/s12630-024-02707-3
A threshold of 100 or more colony-forming units on the anesthesia machine predicts bacterial pathogen detection: a retrospective laboratory-based analysis
Abstract
Purpose: Preventing the spread of pathogens in the anesthesia work area reduces surgical site infections. Improved cleaning reduces the percentage of anesthesia machine samples with ≥ 100 colony-forming units (CFU) per surface area sampled. Targeting a threshold of < 100 CFU when cleaning anesthesia machines may be associated with a lower prevalence of bacterial pathogens. We hypothesized that anesthesia work area reservoir samples returning < 100 CFU would have a low (< 5%) prevalence of pathogens.
Methods: In this retrospective cohort study of bacterial count data from nine hospitals, obtained between 2017 and 2022, anesthesia attending and assistants' hands, patient skin sites (nares, axilla, and groin), and anesthesia machine (adjustable pressure-limiting valve and agent dials) reservoirs were sampled at case start and at case end. The patient intravenous stopcock set was sampled at case end. The isolation of ≥ 1 CFU of Staphylococcus aureus, methicillin-resistant Staphylococcus aureus, Enterococcus, vancomycin-resistant Enterococcus, gram-negative (i.e., Klebsiella, Acinetobacter, Pseudomonas, and Enterobacter spp.) or coagulase-negative Staphylococcus was compared for reservoir samples returning ≥ 100 CFU vs those returning < 100 CFU.
Results: Bacterial pathogens were isolated from 24% (7,601/31,783) of reservoir samples, 93% (98/105) of operating rooms, and 83% (2,170/2,616) of cases. The ratio of total pathogen isolates to total CFU was < 0.0003%. Anesthesia machine reservoirs returned ≥ 100 CFU for 44% (2,262/5,150) of cases. Twenty-three percent of samples returning ≥ 100 CFU were positive for ≥ 1 bacterial pathogen (521/2,262; 99% lower confidence limit, 22%) vs 3% of samples returning < 100 CFU (96/2,888; 99% upper limit, 4%).
Conclusions: Anesthesia machine reservoir samples returning < 100 CFU were associated with negligible pathogen detection. This threshold can be used for assessment of terminal, routine, and between-case cleaning of the anesthesia machine and equipment. Such feedback may be useful because the 44% prevalence of ≥ 100 CFU was comparable to the 46% (25/54) reported earlier from an unrelated hospital.
RéSUMé: OBJECTIF: La prévention de la propagation des agents pathogènes dans la zone de travail de l’anesthésie réduit les infections du site opératoire. L’amélioration du nettoyage réduit le pourcentage d’échantillons de l’appareil d’anesthésie présentant ≥ 100 unités de formation de colonie (UFC) par surface échantillonnée. Le fait de cibler un seuil < 100 UFC lors du nettoyage des appareils d’anesthésie pourrait être associé à une prévalence plus faible d’agents pathogènes bactériens. Nous avons émis l’hypothèse que les échantillons des réservoirs de la zone de travail d’anesthésie < 100 UFC résulteraient en une faible prévalence (< 5 %) d’agents pathogènes. MéTHODE: Dans cette étude de cohorte rétrospective des données de décompte bactérien de neuf hôpitaux, obtenues entre 2017 et 2022, les mains des anesthésiologistes et des assistant·es en anesthésie, les sites cutanés des patient·es (narines, aisselles et aines) et les réservoirs de l’appareil d’anesthésie (soupape de réglage de limitation de pression et cadrans d’agent) ont été échantillonnés au début et à la fin de chaque cas. Les échantillons sur l’ensemble de robinets d’arrêt intraveineux des patient·es ont été prélevés à la fin de chaque cas. L’isolement de ≥ 1 UFC de staphylocoque doré, de staphylocoque doré résistant à la méthicilline, d’entérocoque, d’entérocoque résistant à la vancomycine, de staphylocoque à Gram négatif (c.-à-d. Klebsiella, Acinetobacter, Pseudomonas et Enterobacter spp.) ou à coagulase négative a été comparé pour les échantillons de réservoir retournant ≥ 100 UFC vs ceux qui comportaient < 100 UFC. RéSULTATS: Des bactéries pathogènes ont été isolées dans 24 % (7601/31 783) des échantillons de réservoir, 93 % (98/105) des salles d’opération et 83 % (2170/2616) des cas. Le rapport entre le nombre total d’isolats d’agents pathogènes et le nombre total d’UFC était de < 0,0003 %. Les échantillons pris sur les réservoirs d’appareils d’anesthésie ont retourné ≥ 100 UFC dans 44 % (2262/5150) des cas. Vingt-trois pour cent des échantillons retournés ≥ 100 UFC étaient positifs pour ≥ 1 agent pathogène bactérien (521/2262; limite de confiance inférieure à 99 %, 22 %) vs 3 % des échantillons retournant < 100 UFC (96/2888 ; 99 % de la limite supérieure, 4 %). CONCLUSION: Les échantillons pris sur les réservoirs de l’appareil d’anesthésie comportant < 100 UFC étaient associés à une détection négligeable d’agents pathogènes. Ce seuil peut être utilisé pour l’évaluation du nettoyage final, de routine et entre les cas de l’appareil et de l’équipement d’anesthésie. Une telle rétroaction peut être utile parce que la prévalence de 44 % de ≥ 100 UFC était comparable aux 46 % (25/54) rapportés précédemment dans un autre hôpital.
Keywords: anesthesia machines; bacterial load; hospital hygiene; operating rooms; pathogens.
© 2024. Canadian Anesthesiologists' Society.
Similar articles
-
Impact of Shipping Transit Time on Central Laboratory Processing of Total Colony Forming Units (CFU) and Staphylococcus aureus Detection.Cureus. 2025 Mar 14;17(3):e80590. doi: 10.7759/cureus.80590. eCollection 2025 Mar. Cureus. 2025. PMID: 40236356 Free PMC article.
-
Estimation of the contribution to intraoperative pathogen transmission from bacterial contamination of patient nose, patient groin and axilla, anesthesia practitioners' hands, anesthesia machine, and intravenous lumen.J Clin Anesth. 2024 Feb;92:111303. doi: 10.1016/j.jclinane.2023.111303. Epub 2023 Oct 22. J Clin Anesth. 2024. PMID: 37875062
-
Transmission dynamics of gram-negative bacterial pathogens in the anesthesia work area.Anesth Analg. 2015 Apr;120(4):819-26. doi: 10.1213/ANE.0000000000000626. Anesth Analg. 2015. PMID: 25790209 Clinical Trial.
-
Literature review on the distribution characteristics and antimicrobial resistance of bacterial pathogens in neonatal sepsis.J Matern Fetal Neonatal Med. 2022 Mar;35(5):861-870. doi: 10.1080/14767058.2020.1732342. Epub 2020 Feb 26. J Matern Fetal Neonatal Med. 2022. PMID: 32102584 Review.
-
Sulopenem: An Intravenous and Oral Penem for the Treatment of Urinary Tract Infections Due to Multidrug-Resistant Bacteria.Drugs. 2022 Apr;82(5):533-557. doi: 10.1007/s40265-022-01688-1. Epub 2022 Mar 16. Drugs. 2022. PMID: 35294769 Review.
Cited by
-
The efficacy of a nitric oxide-releasing formulation on nares isolated Methicillin-Resistant Staphylococcus aureus in porcine wound infection model.Front Cell Infect Microbiol. 2024 Dec 3;14:1501360. doi: 10.3389/fcimb.2024.1501360. eCollection 2024. Front Cell Infect Microbiol. 2024. PMID: 39691695 Free PMC article.
-
Surface Cleaning with a Microfiber Cloth and Water followed by Ultraviolet-C Light Exposure Achieves Non-Inferior Disinfection of a Pathogenic Staphylococcus aureus Strain versus Use of Germicidal Wipes.Cureus. 2024 Aug 1;16(8):e65963. doi: 10.7759/cureus.65963. eCollection 2024 Aug. Cureus. 2024. PMID: 39221375 Free PMC article.
-
Frequently Touched Sites in the Intensive Care Unit Environment Returning 100 Colony-Forming Units per Surface Area Sampled Are Associated With Increased Risk of Major Bacterial Pathogen Detection.Cureus. 2024 Aug 31;16(8):e68317. doi: 10.7759/cureus.68317. eCollection 2024 Aug. Cureus. 2024. PMID: 39350803 Free PMC article.
-
Importance of Ultraviolet-C (UV-C) Emitter Configuration for the Attenuation of Staphylococcus aureus and Candida auris Pathogens.Cureus. 2024 Oct 16;16(10):e71612. doi: 10.7759/cureus.71612. eCollection 2024 Oct. Cureus. 2024. PMID: 39553089 Free PMC article.
-
Impact of Shipping Transit Time on Central Laboratory Processing of Total Colony Forming Units (CFU) and Staphylococcus aureus Detection.Cureus. 2025 Mar 14;17(3):e80590. doi: 10.7759/cureus.80590. eCollection 2025 Mar. Cureus. 2025. PMID: 40236356 Free PMC article.
References
-
- Antimicrobial Resistance Collaborators. Global burden of bacterial antimicrobial resistance in 2019: a systematic analysis. Lancet 2022; 399: 629–55. https://doi.org/10.1016/s0140-6736(21)02724-0 - DOI
-
- Boucher HW, Talbot GH, Bradley JS, et al. Bad bugs, no drugs: no ESKAPE! An update from the Infectious Diseases Society of America. Clin Infect Dis 2009; 48: 1–12. https://doi.org/10.1086/595011 - DOI - PubMed
-
- Loftus RW, Dexter F, Brown JR. Transmission of Staphylococcus aureus in the anaesthesia work area has greater risk of association with development of surgical site infection when resistant to the prophylactic antibiotic administered for surgery. J Hosp Infect 2023; 134: 121–8. https://doi.org/10.1016/j.jhin.2023.01.007 - DOI - PubMed - PMC
-
- Menzel J, Kühn A, Beck D, Schock B, Chaberny IF. Hand hygiene in the operating room (OR)-(not) an issue? [German]. Unfallchirurgie (Heidelb) 2023; 126: 563–8. https://doi.org/10.1007/s00113-022-01181-0 - DOI - PubMed
-
- Dexter F, Loftus RW. Estimation of the contribution to intraoperative pathogen transmission from bacterial contamination of patient nose, patient groin and axilla, anesthesia practitioners' hands, anesthesia machine, and intravenous lumen. J Clin Anesth 2024; 92: 111303. https://doi.org/10.1016/j.jclinane.2023.111303 - DOI - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous