. 2023 Dec 31;19(13):1348-1352.
doi: 10.6026/973206300191348. eCollection 2023.

Effect of NaOCl on cyclic fatigue resistance

Affiliations

Effect of NaOCl on cyclic fatigue resistance

Akshayraj Langaliya et al. Bioinformation. .

Abstract

The impact of 5.25 percent NaOCL on the resistance offered by TruNatomy, Hero Gold and ProtaperGold against cyclic fracture as against the treatment of NiTi rotary files with distilled water is of interest to dentists. Inside the stainless steel blocks, man-made canals were created for the purpose of testing the cyclic fatigue. 60 endodontic files were taken as study specimens. It was observed that values of number of cycles to fracture in NaOCl among three file systems were in the order of TruNatomy (1053.50 ± 134.81)>Hero Gold (652.66 ± 58.66) > ProtaperGold (494.50 ± 47.69). The TruNatomy file system reflected greatest cyclic fatigue resistance. It was also found that cyclic fatigue resistance in NiTi rotary files studied here is not hampered by 5.25% NaOCl.

Keywords: Cyclic fatigue; HeroGold; Protaper Gold; TruNatomy; resistance to cyclic fracture.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Shen Y, et al. J Endod . 2013;39:163. - PubMed
    1. Elnaghy AM, et al. BMC Oral Health . 2020;20:1. - PMC - PubMed
    1. Uygun AD, et al. Niger J Clin Pract . 2020;23:41. - PubMed
    1. Pruett JP, et al. J Endod . 1997;23:77. - PubMed
    1. Kaval ME, et al. J Endod . 2016;42:1840. - PubMed

LinkOut - more resources