. 2024 Mar;32(3):685-692.
doi: 10.1002/ksa.12088. Epub 2024 Feb 28.

High three-dimensional accuracy of component placement and lower limb alignment using a robotic arm-assisted system and gap-balancing instrument in total knee arthroplasty

Affiliations

High three-dimensional accuracy of component placement and lower limb alignment using a robotic arm-assisted system and gap-balancing instrument in total knee arthroplasty

Emanuele Diquattro et al. Knee Surg Sports Traumatol Arthrosc. 2024 Mar.

Abstract

Purpose: It was hypothesized that robotic arm-assisted total knee arthroplasty (RA-TKA) using additionally a gap-balancing instrumentation will show high accuracy in executing the planning in femoral and tibial component placement throughout the range of knee motion (ROM) during TKA surgery.

Methods: Prospectively collected data were analysed for patients undergoing RA-TKA. A cruciate retaining cemented design was implanted using the MAKO® robotic system. Lower limb alignment at 0°, 30°, 45°, 60° and 90° of flexion was recorded at the beginning of surgery and finally after implantation of the components. A ligament tensioner was inserted after tibial precut to measure the extension and flexion gap, and final component placement was planned based on 3D CT images. Femoral and tibial component placement was measured in all three planes.

Results: A total of 104 patients were included (mean age 69.4 ± 9 years; 44 male, 60 female). The difference in component placement after planning and final implantation showed less valgus of 0.7° ± 1.4° (p < 0.001), less external rotation of 0.6° ± 1.9° (p = 0.001) and less flexion of 0.9° ± 1.8° (p < 0.001) for the femoral component. The tibial component was placed in more varus of 0.2° ± 0.9° (p = 0.056) and more posterior slope of 0.5° ± 0.9° (p < 0.001). The lower limb alignment in extension was 4.4° ± 5.2° of varus of the native knee and changed to 1.2° ± 1.9° of varus after TKA (p < 0.01).

Conclusion: Robotic-assisted TKA helps to achieve the target of alignment and component placement very close to the planning. It allows optimal component placement of off-the-shelf implants respecting patient's specific anatomy.

Level of evidence: Level II.

Keywords: MAKO; functional alignment; joint line; ligament tension; robotics; total knee arthroplasty.

PubMed Disclaimer

References

REFERENCES

    1. Agarwal N, To K, McDonnell S, Khan W. Clinical and radiological outcomes in robotic-assisted total knee arthroplasty: a systematic review and meta-analysis. J Arthroplasty. 2020;35:3393-3409. https://doi.org/10.1016/j.arth.2020.03.005
    1. Batailler C, Fernandez A, Swan J, Servien E, Haddad FS, Catani F, et al. MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2021;29:3585-3598. https://doi.org/10.1007/s00167-020-06283-z
    1. Bhimani SJ, Bhimani R, Smith A, Eccles C, Smith L, Malkani A. Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty. Bone Joint Open. 2020;1:8-12. https://doi.org/10.1302/2633-1462.12.BJO-2019-0004.R1
    1. Chin BZ, Tan SSH, Chua KCX, Budiono GR, Syn NL-X, O'Neill GK. Robot-assisted versus conventional total and unicompartmental knee arthroplasty: a meta-analysis of radiological and functional outcomes. J Knee Surg. 2021;34:1064-1075. https://doi.org/10.1055/s-0040-1701440
    1. Choi BS, Kim SE, Yang M, Ro DH, Han H-S. Functional alignment with robotic-arm assisted total knee arthroplasty demonstrated better patient-reported outcomes than mechanical alignment with manual total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2023;31:1072-1080. https://doi.org/10.1007/s00167-022-07227-5

Grants and funding